background image

DAIHAN  Scientific,  Air-jacketed  CO2  Incubators                                                                                                      2/14 

1.1. 

 

   

 

 

 

Tables of Contents

 

1.1.  목  차

 ································································· 2 

1.2.  작동하기  전에

······················································ 2 

1.3.  제품  규격

 ··························································· 3 

1.4.  제품  설명

 ··························································· 4 

1.5.  부분별  명칭  및  동작  기능

 ····································· 5 

1.6.  작동방법

 ····························································· 7 

1.7. HEPA Filter  교체  방법

 ··········································· 11 

1.8.  주의사항

 ····························································· 12 

1.9.  고장의  원인  및  처리

 ············································· 12 

 

 

1.2. 

작동하기  전에       

주식회사  대한과학의  제품을  구입해  주셔서  감사합니다. 

본  설명서는  기기의  기능과  취급상의  주의점에  대한  기술,  사

용자의  안전과  원활한  기기  작동방법을  익히기  위한  설명서 

이오니  잘  읽어  보시고  숙지  하시기  바랍니다. 

사용자의  주의가  반드시  필요한  부분에는  아래와  같은  경고 

표시가  있습니다.  각  경고  표시와  그  의미를  숙지  하시어  안전 

사고에  미리  대비  하시기  바랍니다.   

 

경  고 

이  표시는  주의사항을  지키지  않았을  경우  사용자가  부상을 
입을  수  있음을  알립니다. 

 
주  의 

이  표시는  주의사항을  지키지  않았을  경우  기기의  고장의  원
인이  됨을  알립니다. 
 

알  림 

이  표시는  기능상  주요한  사항이나  사용자가  반드시  숙지해
야  할  사실을  알립니다.   
 

고  온  주  의 

이  표시는  고온의  히터를  사용하므로  화상의  위험이  있음을 
알립니다. 
 

폭  발  위  험 

이  표시는  휘발성,  폭발성  화학물질을  사용할  경우  폭발의  위
험이  있음을  알립니다.   
 

접  근  금  지 

기기의  사용  중에  사용자의  접근을  제한함을  알립니다. 
 

HOT

 

Summary of Contents for ICA-100

Page 1: ...Incubators 1 14 Air jacketed CO2 Incubator Certifications by ISO 9001 Certified PL Insurance User Manual Version 1 0 0 written for Air jacketed CO2 Incubator ICA 100 150 models ICA 100 Air jacketed CO...

Page 2: ...wn below where user s attention is absolutely necessary Please familiarize yourself with each warning sign and its meaning to prepare for a safety accident Warning Warning alerts you to a possibility...

Page 3: ...DAIHAN Scientific Air jacketed CO2 Incubators 3 14 1 3 Product Specifications...

Page 4: ...r settings It also equipped with a circuit breaker which protects from short circuit PID A controller function that automatically adjusts the power supplied to the heater and adjustable shelves for us...

Page 5: ...on UV Lamp Lit up when inside of the chamber is sterilized by UV lamp AT Lamp This is an indicator lamp lit up when Auto Tuning function is used to optimize PID control value of temperature and CO2 ga...

Page 6: ...of the device AUTO TUNE ENTER Button This button is used to enter the set value Also press and hold this button for more than 5 seconds to proceed to the Auto Tuning screen 1 9 Button Input numbers B...

Page 7: ...the chamber PROGRAM MODE is a mode to change the internal environment of the chamber up to 10 STEPs How to set NORMAL Manual mode In the NORMAL mode press the MODE button on the main controller to set...

Page 8: ...he ENTER button to the next set value After all the settings are completed press the MODE button to go to the next step display screen At this point setting the Timer value to 00 00 does not let go to...

Page 9: ...STEP If you press it in the last step it goes back to the first step How to set UV Lamp UV Lamp can not operate when temperature and CO2 control is active When the mode button is pressed twice during...

Page 10: ...n it is running the AUTO TUNING screen appears Select the control item to be AUTO TUNED by using the ENTER key and press the MODE key to perform AUTO TUNING for the selected item Please be sure to exe...

Page 11: ...DAIHAN Scientific Air jacketed CO2 Incubators 11 14 1 7 How to replace HEPA Filter Option...

Page 12: ...lugging the power cord do not hold the cord but pull the plug 5 Be careful not to let liquid flow into the controller part of the instrument 6 Do not use volatile flammable or explosive chemicals as t...

Page 13: ...emperature Protection Check Over temperature protection value Set protection temperature higher than the usual operating temperature Heater disconnection Check heater disconnection Replace heater conn...

Page 14: ...his instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This certification is only for interna...

Page 15: ...rs 1 14 Air jacketed CO2 Incubator Certifications by ISO 9001 Certified PL Insurance Version 1 0 0 written for Air jacketed CO2 Incubator ICA 100 150 models ICA 100 Air jacketed CO2 Incubator 101 Lit...

Page 16: ...DAIHAN Scientific Air jacketed CO2 Incubators 2 14 1 1 Tables of Contents 1 1 2 1 2 2 1 3 3 1 4 4 1 5 5 1 6 7 1 7 HEPA Filter 11 1 8 12 1 9 12 1 2 HOT...

Page 17: ...DAIHAN Scientific Air jacketed CO2 Incubators 3 14 1 3...

Page 18: ...DAIHAN Scientific Air jacketed CO2 Incubators 4 14 1 4 CO2 CO2 INCUBATOR 50 PID A Controller PID A...

Page 19: ...cientific Air jacketed CO2 Incubators 5 14 1 5 1 5 1 LCD Heating Lamp Program Mode Lamp CO2 Lamp CO2 Timer Lamp UV Lamp UV AT Lamp CO2 PID Auto Tuning TEMP H L Lamp High Low Alarm CO2 H L Lamp CO2 CO2...

Page 20: ...ientific Air jacketed CO2 Incubators 6 14 START Button PROGRAM NORMAL Button Program mode Normal mode MODE Button CO2 Timer AUTO TUNE ENTER Button 5 Auto Tuning 1 9 Button Button Mute Button UV Button...

Page 21: ...jacketed CO2 Incubators 7 14 1 6 LCD 3 CO2 Gas Door NORMAL MODE PROGRAM MODE T Co2 Co2 D Hum Tm SvT NORMAL MODE PROGRAM MODE 10STEP NORMAL NORMAL MODE LCD Temp T CO2 Door Temp D Timer Tm SHIFT ENTER...

Page 22: ...ncubators 8 14 PROGRAM NORMAL 5 Program 5 PROGRAM 10STEP STEP MODE STEP Temp T CO2 Door Temp D Timer Tm SHIFT ENTER MODE STEP Timer 00 00 STEP STEP MODE STEP CYCLE Run Cycle No STEP 999 000 UV LAMP Ti...

Page 23: ...eted CO2 Incubators 9 14 EX Step1 Step5 60 1 Step1 Step5 Mode Enter SHIFT 2 Step6 Tm 00 00 3 Mode Cycle Number Cycle Number 60 4 Mode START STEP SKIP STEP STEP UV Lamp UV Lamp CO2 Mode 2 UV Lamp UV La...

Page 24: ...2 Incubators 10 14 AUTO TUNING AUTO TUNING CO2 PID AUTO TUNING CO2 AUTO TUNING START AUTO TUNE 5 AUTO TUNING AUTO TUNING ENTER MODE AUTO TUNING 10 20 CO2 Gas Panel Power Plug Socket CO2 Gas Inlet Port...

Page 25: ...DAIHAN Scientific Air jacketed CO2 Incubators 11 14 1 7 HEPA Filter Option...

Page 26: ...DAIHAN Scientific Air jacketed CO2 Incubators 12 14 1 8 1 AC 220V 50 60Hz 2 3 4 5 6 7 8 70 1 9 NONE NONE NONE nnnn PT PT uuuu PT PT 60 uuuu uuuu uuuu...

Page 27: ...Incubators 13 14 CERTIFICATION Air jacketed CO2 Incubator ICA 100 ICA150 24 1 2 2 24 1 2 2 3 4 326 Call Center 080 008 3000 A S 02 967 5235 FAX 033 737 7575 02 967 5258 9 Email info daihansci co kr ww...

Page 28: ...1 461 3 051 517 6116 051 517 6318 11 59 422 02 967 5978 02 967 5979 11 59 323 02 967 5941 02 967 5931 11 59 417 02 3673 0322 02 965 5163 21 35 12 101 070 4304 5287 070 8270 0060 1 204 26 301 031 430 2...