Installation Guide 10
Figure 2-12
Table 2-8
Port
Wiring Terminal
Description
Alarm output
OUT1+
ALM-IN triggers alarm
output.
Door
timeout
and
intrusion alarm output.
Tamper alarm output of
reader
Internal
and
external
alarm output ports are
able to connect audible
and visual sirens.
OUT1-
2.4.7 Description of Alarm Input and Output Rule
In case of alarm event, the alarm continues for 15s. Please refer to Table 2-9 for detailed alarm
input and output rules.
Table 2-9
Alarm Type
Alarm Signal Input
Port
Alarm Signal Output
Port
Alarm Status
External alarm
input
ALM1
OUT1
Link all doors to be
normally open.
Internal alarm
input
SR1
OUT1
Door timeout, intrusion
alarm and reader tamper
alarm trigger external
alarm to give an alarm.
SR2
SR3
SR4
RS-485/CASE
RS-485/CASE
RS-485/CASE
RS-485/CASE
2.5 DIP Switch
Operate with DIP switch.