background image

 

Installation  Guide  11 

Figure 2-13  

 

 

the switch is at ON position, meaning 1. 

 

the switch is at the bottom, meaning 0. 

 

1

8 are all 0; the system is started normally. 

 

1

8 are all 1; the system enters BOOT mode after start. 

 

1, 3, 5 and 7 are 1, while others are 0. After reboot, the system restores factory defaults. 

 

2, 4, 6 and 8 are 1, while others are 0. After reboot, the system restores factory defaults, 

but user info is retained.   

2.6 Reboot 

Insert a needle into reboot hole, press it once to reboot the device. 

 

Reboot button is to reboot the device, rather than modifying configuration.   

Summary of Contents for ASC1204B

Page 1: ...Four door One way Access Controller User s Manual V1 0 0...

Page 2: ...gularly change the credentials to your devices to help ensure that only authorized users are able to access the system 2 Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems...

Page 3: ...em is set up for multiple users ensure that each user only has rights to features and functions they need to use to perform their job 10 UPnP UPnP will automatically try to forward ports in your route...

Page 4: ...ras to the PoE Ports on the Back of an NVR Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and cannot be accessed directly 16 Isolate NVR and IP Camera Net...

Page 5: ...ese limits are designed to provide reasonable protection against harmful interference in a commercial environment Operation of this equipment in a residential area is likely to cause harmful interfere...

Page 6: ...ght collect personal data of others such as face fingerprints car plate number Email address phone number GPS and so on You need to be in compliance with the local privacy protection laws and regulati...

Page 7: ...ations description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader software or try other mainstream reader software if the Guide in PDF for...

Page 8: ...put and output range Please don t dismantle the device arbitrarily Please transport use and store the device within allowed humidity and temperature range Power Requirement Please make sure to use bat...

Page 9: ...and Output Rule 10 2 5 DIP Switch 10 2 6 Reboot 11 3 Smart PSS Config 12 3 1 Login Client 12 3 2 Add Access Controller 12 3 2 1 Auto Search 12 3 2 2 Manual Add 14 3 3 Add User 16 3 3 1 Card Type 17 3...

Page 10: ...Table of Contents IX 7 Question Online upgrade of the device 25 8 Question Max wiring distance and transmission distance of card reader and controller 25 5 Technical Parameters 26...

Page 11: ...larm 1 Support 5 groups of control output electric lock 4 and alarm output 1 With RS485 port it may extend to connect control module FLASH storage capacity is 16M which may extend to 32M Support max 1...

Page 12: ...Overview 2 Figure 1 2...

Page 13: ...ock and reader is shown in Figure 2 1 Figure 2 1 2 2 Device Installation There are two installation modes Mode 1 fix the whole device onto the wall with screws Mode 2 with U shaped guide rail hang the...

Page 14: ...nto upper groove of the U shaped guide rail Step 3 Push the snap joint at the bottom of the device upwards The installation is completed when you hear the fitting sound 2 3 Disassembly If the device i...

Page 15: ...e an alarm Device wiring diagram is shown in Figure 2 5 Figure 2 5 Interfaces are described in Table 2 1 Table 2 1 No Port Description No Port Description 1 RS485 communication 7 Reader of door 1 2 Ex...

Page 16: ...and door contact are shown in Figure 2 6 Please refer to Table 2 3 for descriptions of wiring terminals Figure 2 6 Table 2 3 Port Wiring Terminal Description Exit button door contact PUSH1 Exit button...

Page 17: ...y exit button of door 4 and door contact input of door 4 SR4 Door contact input of door 4 2 4 3 Wiring Description of Lock Support 4 groups of lock control outputs serial numbers after the terminals r...

Page 18: ...only supports to connect one type of reader 485 or Wiegand Please refer to Table 2 5 for descriptions of wiring terminals corresponding to readers Take door 1 for example other readers are the same P...

Page 19: ...ternal alarm input ports are able to connect smoke detector and IR detector etc When external alarm is triggered all doors are linked to be normally open GND 2 4 6 Wiring Description of Alarm Output W...

Page 20: ...Input and Output Rule In case of alarm event the alarm continues for 15s Please refer to Table 2 9 for detailed alarm input and output rules Table 2 9 Alarm Type Alarm Signal Input Port Alarm Signal...

Page 21: ...enters BOOT mode after start 1 3 5 and 7 are 1 while others are 0 After reboot the system restores factory defaults 2 4 6 and 8 are 1 while others are 0 After reboot the system restores factory defaul...

Page 22: ...rts for different versions Please refer to actual port 3 1 Login Client Install the matching Smart PSS client and double click to run Carry out initialization configuration according to interface prom...

Page 23: ...cific operations please refer to User s Manual of Smart PSS Client Step 3 Select the device that needs to be added and click Add The system pops up Prompt Step 4 Click OK The system displays Login Inf...

Page 24: ...e port user name and password Alternatively double click the device to enter Modify Device interface Click this icon to enter Device Config interface and configure device camera network event storage...

Page 25: ...fill in according to actual conditions Group Name Select the group of the device User Name and Password User name and password of the device Step 3 Click Add to add a device The system displays the ad...

Page 26: ...Smart PSS Config 16 Figure 3 7 3 3 Add User Add users and bind with cards so as to distribute authority In New interface click Access to enter Access interface and complete access config here...

Page 27: ...17 Figure 3 8 3 3 1 Card Type Card type shall be the same with card issuer otherwise it fails to read card number In Access interface click and then click to set the card type as shown in Figure 3 9...

Page 28: ...gure 3 9 Figure 3 10 3 3 2 Single Add Add a single user send a card and input user info Step 1 In Access interface click and then click as shown in Figure 3 11 The system pops up Add User dialog box a...

Page 29: ...Smart PSS Config 19 Figure 3 11 Figure 3 12 Step 2 Add user info manually including basic info fingerprint info and details Please refer to Table 3 3 for details...

Page 30: ...e it only applies to guest card Valid Time set the valid time of card which is 10 years by default Picture user picture max 120K Card no and user ID cannot be repeated Fingerprint Info Collect fingerp...

Page 31: ...Smart PSS Config 21 Figure 3 13 Step 2 Click Add The system pops up Add Door Group dialog box as shown in Figure 3 14 Figure 3 14...

Page 32: ...to Door Group Select a door group add corresponding users to the group so all users in the group obtain authority of all doors in the group Step 1 In Access interface click and then click Access Level...

Page 33: ...zation The search list filters user info without card number In the user list cancel the added user and delete the user s authority 3 5 2 Authorize According to User Select a user distribute door grou...

Page 34: ...Smart PSS Config 24 Figure 3 17 Step 2 Click The system pops up Select Door Group dialog box as shown in Figure 3 18 Figure 3 18 Step 3 Select the door group and click OK to finish authorization...

Page 35: ...ect the device Answer Please check whether TCP IP connector is connected properly and whether device IP is in the same network segment 4 Question After swiping card it prompts that card is invalid Ans...

Page 36: ...of connected reader 4 groups Working power supply Rated voltage 10V 15V DC rated current 0 75A Period 128 Holiday 128 Unlocking mode Card card password password card or password card fingerprint finge...

Reviews: