Figure 3-30 Wired zone
Step 3
Tap the wired zone name to configure the zone.
Table 3-9 Description of wired zone parameters
Parameter
Description
Zone No.
The number cannot be modified.
Zone Type
Select the corresponding type according to the detector type, including
IR, gas, smoke detector, emergency button, door detector, burglar,
perimeter and doorbell. Different types have different icons displayed.
NO/NC
Select NO (normally open) or NC (normally closed) according to the
detector type. It must be the same as the detector type.
Alarm Status
●
Instant Alarm : When armed, if an alarm is triggered, the device
produces a siren at once and enters the alarm status.
●
Delay Alarm : When armed, if an alarm is triggered, the device enters
the alarm status after a specified time, during which you can disarm
and cancel the alarm.
●
Bypass : Alarms will not be triggered in the area. After the area is
disarmed, it will be restored to its normal working status.
●
Remove : The area is invalid during arming and disarming.
●
24 Hour : Alarms will be triggered all the time in the area, regardless
of whether it is armed or disarmed.
A zone in the Remove status cannot be bypassed.
55
Summary of Contents for VTH5422HB-W
Page 1: ...V1 0 0 Digital VTH Version 4 7 User s Manual...
Page 9: ...1 1 2 VTH2621G VTH2622G Series Figure 1 2 Front panel 2...
Page 12: ...1 1 5 VTH5421E Series Figure 1 5 Front panel 5...
Page 13: ...1 1 6 VTH5421H VTH5422H Series Figure 1 6 Front panel 6...
Page 14: ...1 1 7 VTH5441G Series Figure 1 7 Front panel 7...
Page 87: ...Figure 3 59 DSS QR code Figure 3 60 DMSS QR code 80...
Page 90: ...Figure 3 62 Cloud update 83...
Page 98: ...Figure 4 8 Monitor screen Step 2 Tap select the VTO from the channel list as needed 91...
Page 124: ...Figure 5 18 Obtain the QR code 117...