background image

 

 

 

If the unit is damaged and requires service, unplug the unit from the main AC power supply and 

from the PoE supply and refer to qualified service personnel. Damage may include, but is not 

limited to: 

  The power supply cord or plug is damaged. 

  Liquid has spilled in or on the unit. 

  An object has fallen on the unit. 

  The unit has been dropped and the housing is damaged. 

  The unit displays a marked change in performance. 

  The unit does not operate in the expected manner when the user correctly follows the proper 

operating procedures. 

 

Ensure a service technician uses replacement parts specified by the manufacturer, or that have 

the same characteristics as the original parts. Unauthorized parts may cause fire, electrical 

shock, or other hazards. Dahua is not liable for any damage or harm caused by unauthorized 

modifications or repairs. 

 

Perform safety checks after completion of service or repairs to the unit.  

 

Use attachments and accessories only specified by the manufacturer. Any change or 

modification of the equipment, not expressly approved by Dahua, could void the warranty.  

 

Incorporate a readily accessible disconnect device in the building installation wiring for quick 

power disconnect to the camera. 

 

Dahua assumes no liability or responsibility for any fire or electrical shock caused by improper 

handling or installation.  

Environmental Precautions 

 

Do not aim the unit at a strong light source or into direct sunlight to focus. A strong light source 

may cause overexposure and may affect the longevity of the CCD or the CMOS sensor. 

 

Transport, use, and store the unit within the specified temperature and humidity range.  

 

Do not place the unit in a wet, dusty, extremely hot or an extremely cold environment; and avoid 

environments with strong electromagnetic radiation or unstable lighting.  

 

Never push objects of any kind into this unit through openings as they may touch dangerous 

voltage points or cause a short circuit that may result in fire or electrical shock. Take care to not 

spill any liquid on the unit.  

 

Do not use units intended for indoor applications near water, in damp or wet environments, or in 

any area classified as a wet location. Do not expose an indoor unit to rain or moisture to reduce 

the risk of fire or electric shock. 

 

Do not block or cover any openings in the unit enclosure. These openings are provided for 

ventilation to prevent overheating and to ensure reliable operation. Ensure the unit is placed in 

an area with adequate ventilation.  

 

Do not place the unit near a heat source such as heaters, stoves, radiators or other equipment 

that produces heat. 

 

Pack the unit with standard factory packaging or material of the same quality when transporting 

the unit.  

 

Take care to avoid heavy stress, violent vibration, or water spills to the camera unit during 

transportation, storage, and installation. 

Summary of Contents for 59230UNI

Page 1: ...2 MP Network PTZ Network Camera 59230UNI Quick Start Guide Version 001 001 Dahua Technology USA Inc...

Page 2: ...Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 7 3 3 Alarm...

Page 3: ...protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have pow...

Page 4: ...ng or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of...

Page 5: ...wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the d...

Page 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Page 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Page 8: ...o transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed...

Page 9: ...ce only Figure 3 1 Dimensions for 59230IC 3 2 Wiring The dome camera includes the following wiring bundles Wire Color Connection Power Red 24 VAC Yellow Green Earth Ground Black 24 VAC Video Control B...

Page 10: ...ves the alarm input signal If input signal is grounded then no alarm input signal is detected Figure 3 2 Alarm Output Level Application Use this alarm output configuration if the output triggers an ex...

Page 11: ...nt substitute as these cards have been fully tested without issue and the SanDisk Extreme line is better suited for constant recording Lower grade SD cards meant for multimedia applications will at ti...

Page 12: ...de a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I C...

Page 13: ...t to the installation medium The hardware must be capable of supporting eight 8 times the weight of the camera and mount Appropriate tools to mount the camera to the wall Unpacking the Camera 1 Remove...

Page 14: ...ule 6 Re assemble the camera module secure back into the dome and then replace the rear panel 4 3 Mounting the Camera to a Wall 1 Place the PFB300S Wall Mount against the wall and mark the location of...

Page 15: ...Tighten the set screw on the wall mount to secure the mount adapter Figure 4 3 7 Use the four 4 hex screws and flat washers to secure the wall mount bracket to the wall Figure 4 4 8 Pull the composite...

Page 16: ...apter block firmly Note Ensure the M6 screws are tightly fixed to secure the dome to the wall mount Figure 4 5 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2...

Page 17: ...and automate the assignment of IP addresses DHCP should only be enabled if using dynamic IP address notification or if the DHCP can update a DNS server TFTP The Trivial File Transfer Protocol is a sim...

Page 18: ...figTool to access and to modify the network settings of a device Refer to the Operation Manual available on the CD included with the camera or on Dahuasecurity com for complete information Notes Ensur...

Page 19: ...have different Web interfaces the figures below are for reference only and may not represent the Web Interface for your camera Refer to the Web Operation Manual included on the CD shipped with the ca...

Page 20: ...or Normally Closed NC 3 Check the Relay Out box to enable the alarm activation function 4 Select an alarm output port to activate a corresponding alarm device when an alarm occurs Check Send Email to...

Page 21: ...following Micro SD card alarm options No SD Card Device triggers an alarm if the device does not contain a Micro SD card Capacity Warning Device triggers an alarm when the data on the Micro SD card pa...

Page 22: ...to a specified user after the device triggers an alarm 9 Set the capacity limit for the Micro SD Card available with the Capacity Warning event type The device triggers an alarm once the amount of da...

Page 23: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change...