1  Welcome 

This manual offers reference material and general information about the basic operation, 

maintenance, and troubleshooting of the Dahua Multi-Sensor Panoramic Camera. Read, follow, and 

retain the following safety instructions. Heed all warning on the unit and in the operating instructions 

before operating the unit. Keep this guide for future reference. 

1.1  Important Safeguards and Warnings  

Electrical safety 

 

Install the unit in accordance with the manufacturer’s instructions and in accordance with 

applicable local codes.  

 

All installation and operation must conform to your local electrical safety codes.  

 

Do not overload outlets and extension cords, which may cause fire or electrical shock. 

 

Do not place the camera near or in a place where the camera may contact overhead power lines, 

power circuits, or electrical lights. 

 

Ensure power conforms to SELV (Safety Extra Low Voltage) and that the limited power source is 

rated AC 24V as specified in IEC60950-1. (Power supply requirement is subject to the device 

label). 

 

All input/output ports are SELV circuits. Ensure that SELV circuits are connected only to other 

SELV circuits.  

 

Ground the unit using the ground connection of the power supply to protect the unit from damage, 

especially in damp environments. 

 

Protect the plug and power cord from foot traffic, being pinched, and its exit from the unit. 

 

Units with or without an ON/OFF switch have power supplied to the unit whenever the power 

cord is inserted into the power source; however, the unit is operational only when the ON/OFF 

switch is in the ON position. The power cord is the main power disconnect device for switching 

off the voltage for all units.  

 

Operate the unit only from the type of power source indicated on the label. Before proceeding, 

disconnect the power from the cable to be installed into the unit.  

  For external power supplied units, use only the recommended or approved power supplies. 

  Limited power sources must comply with EN 60950. Substitutions may damage the unit or 

cause fire or shock. 

  For 24 VAC units, voltage applied to the unit’s input power should not exceed ±25%. User-

supplied wiring must comply with local codes (Class 2 power levels). Do not ground the 

supply at the terminals or at the unit’s power supply terminal.  

  Contact the local dealer or the power company to verify the correct power supply.  

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

 

Do not attempt to service the unit. Opening or removing covers may expose you to dangerous 

voltage or other hazards. Refer all servicing to qualified personnel. 

Summary of Contents for 59230UNI

Page 1: ...2 MP Network PTZ Network Camera 59230UNI Quick Start Guide Version 001 001 Dahua Technology USA Inc...

Page 2: ...Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 2 1 Parts List 6 2 2 User supplied Tools and Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 7 3 3 Alarm...

Page 3: ...protect the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have pow...

Page 4: ...ng or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of...

Page 5: ...wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the d...

Page 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Page 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Page 8: ...o transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed...

Page 9: ...ce only Figure 3 1 Dimensions for 59230IC 3 2 Wiring The dome camera includes the following wiring bundles Wire Color Connection Power Red 24 VAC Yellow Green Earth Ground Black 24 VAC Video Control B...

Page 10: ...ves the alarm input signal If input signal is grounded then no alarm input signal is detected Figure 3 2 Alarm Output Level Application Use this alarm output configuration if the output triggers an ex...

Page 11: ...nt substitute as these cards have been fully tested without issue and the SanDisk Extreme line is better suited for constant recording Lower grade SD cards meant for multimedia applications will at ti...

Page 12: ...de a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I C...

Page 13: ...t to the installation medium The hardware must be capable of supporting eight 8 times the weight of the camera and mount Appropriate tools to mount the camera to the wall Unpacking the Camera 1 Remove...

Page 14: ...ule 6 Re assemble the camera module secure back into the dome and then replace the rear panel 4 3 Mounting the Camera to a Wall 1 Place the PFB300S Wall Mount against the wall and mark the location of...

Page 15: ...Tighten the set screw on the wall mount to secure the mount adapter Figure 4 3 7 Use the four 4 hex screws and flat washers to secure the wall mount bracket to the wall Figure 4 4 8 Pull the composite...

Page 16: ...apter block firmly Note Ensure the M6 screws are tightly fixed to secure the dome to the wall mount Figure 4 5 10 Make the proper wiring connections and supply power to the camera Refer to Section 3 2...

Page 17: ...and automate the assignment of IP addresses DHCP should only be enabled if using dynamic IP address notification or if the DHCP can update a DNS server TFTP The Trivial File Transfer Protocol is a sim...

Page 18: ...figTool to access and to modify the network settings of a device Refer to the Operation Manual available on the CD included with the camera or on Dahuasecurity com for complete information Notes Ensur...

Page 19: ...have different Web interfaces the figures below are for reference only and may not represent the Web Interface for your camera Refer to the Web Operation Manual included on the CD shipped with the ca...

Page 20: ...or Normally Closed NC 3 Check the Relay Out box to enable the alarm activation function 4 Select an alarm output port to activate a corresponding alarm device when an alarm occurs Check Send Email to...

Page 21: ...following Micro SD card alarm options No SD Card Device triggers an alarm if the device does not contain a Micro SD card Capacity Warning Device triggers an alarm when the data on the Micro SD card pa...

Page 22: ...to a specified user after the device triggers an alarm 9 Set the capacity limit for the Micro SD Card available with the Capacity Warning event type The device triggers an alarm once the amount of da...

Page 23: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change...