
69
6) LACK OF DRY PERFORMANCE
• Situation : after drying, the clothes still get wet.
cause)
☞
The laurdry amount is more than the recommendation capacity 7.0kg.
☞
Condensing cold water is not supplied.
☞
Clogging Bellows Duct results in poor air circulation.
checking method)
• Situation after drying, the clothes was soaked and hot.
cause)
☞
The dry is done from bad spin performance because of unbalance.
☞
no spin was done before the dry had started.
• Situation : PCB shows "H1" or "H3".
cause)
☞
Thermistor is broken.
☞
Thermistor is short or cut-off.
countermeasures)
☞
replace the Thermistor.
part name
checking point
checking results
jurge
repair method
BELLOWS
DUCT
VALVE INLET
+Condensing
HOSE
clogging
bellows duct
no water supply
from inlet valve
heater was
overheated
owing to poor air
circulation
VALVE INLET
connector slipped
out
VALVE INLET
broken
ill-connection of
condensing hose to
duct pipe
clean the bellow
duct
connect normally
replace valve inlet
connect normally
BELLOW
DUCT
VALVE INLET
CONDENSING
HOSE
Summary of Contents for KUD-UD122RF
Page 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 UD123X SERIES...
Page 12: ...10 1 PANEL F AS 2 UD124X SERIES...
Page 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15...
Page 18: ...16 4 CABINET ASSY...
Page 20: ...18 5 BASE U AS...
Page 22: ...20 6 TUB ASSY...
Page 24: ...22 7 DUCT B AS DUCT PIPE AS...
Page 78: ...76 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor...
Page 80: ...78 8 WIRING DIAGRAM...