65
2) Dry Function Diagram
3) Temp- Time Graph During Dry Cycle
While rotating DRUM, DRY HEATER applice heat to air and FAN blows it into DRUM evaporating water in the laundry.
• Evaporated water is sucked into CONDENSING DUCT, and condensed in DUCT contacting WATER SUPPLY (condensed
water is extracted through DRAIN HOUSING).
• Dry function is performed by continuous repetition of evaporating and condensing circulation as above.
DRY DUCT
T : Thermistor
(CONTROL
HEATER’S
TEMPERATURE )
HEATER
FAN MOTOR
CONDENSING
DUCT
DRUM
DRAIN
HOUSING
온도
건조진행구간
예열
구간
DRUM
내부온도
시간
T
WATER SUPPLY
INSIDE
TEMPERATURE OF
TIME
DRYING PROCESS
ZONE
TEMP.
PRE
HEATING