55
3) H5 Error - Water temperature error in wool/ delicate course
①
In case water temperature in wool/ delicate course is 45
û
C or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
①
Within 15 minutes after heater operation begins;
In case standard temperature is of 42
û
C or lower: If temperature does not increase by 2
û
C or more In
case standard temperature is higher than 42
û
C: If temperature does not increase by1
û
C or more
②
If temperature falls below standard temperature by 2
û
C or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
①
In case washing heater temperature increases by 5
û
C or more within 30 seconds when there is no
water in tank, etc.
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
Summary of Contents for KUD-UD122RF
Page 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 UD123X SERIES...
Page 12: ...10 1 PANEL F AS 2 UD124X SERIES...
Page 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15...
Page 18: ...16 4 CABINET ASSY...
Page 20: ...18 5 BASE U AS...
Page 22: ...20 6 TUB ASSY...
Page 24: ...22 7 DUCT B AS DUCT PIPE AS...
Page 78: ...76 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor...
Page 80: ...78 8 WIRING DIAGRAM...