42
3) Constant temperature control
To minimize the energy consumed by the heater and reduce the time required for washing, the cold water v/v and the hot
water v/v are properly controlled until the required water temperature is reached.
1. After operating the hot water v/v until it reaches the water level where it is possible to detect the water temperature, if it
fails to reach the target temperature, the hot water v/v will continue to operate. If the target temperature is met, then the
cold water v/v is operated.
2. Depending on whether the target temperature is reached, the cold and hot water v/v keeps turning on and off. In other
words, to prevent the water temperature from continuing to rise after reaching the target temperature, the hot water v/v
is turned off and the cold water v/v is turned on. As the cold water is supplied, the water temperature drops and when it
is 5 degrees below the target water temperature, then the hot water v/v is turned on and the cold water v/v is turned off
to raise the water temperature.
3. For the water supply cycle shown in 1 and 2, if the water level is met, then the water supply stops and it moves onto the
next washing cycle.
4. In the earlier stage, the hot water valve is used to supply water. If the hot water valve is closed or not connected then
there would be no difference in water level for 60 seconds. In this case, the constant water temperature control is
ignored and only cold water is supplied.
4) Constant temperature control valve operation algorithm
1. When 30 degrees is selected – target temperature of 35 degrees
30
û
C
35
û
C
Cold water v/v:
Hot water v/v:
10 seconds
2. When 40 degrees is selected – target temperature of 45 degrees
40
û
C
45
û
C
Cold water v/v:
Hot water v/v:
10 seconds
Cold water v/v Off
Hot water v/v On
Cold water v/v On
Hot water v/v Off
Summary of Contents for KUD-UD122RF
Page 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 UD123X SERIES...
Page 12: ...10 1 PANEL F AS 2 UD124X SERIES...
Page 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15...
Page 18: ...16 4 CABINET ASSY...
Page 20: ...18 5 BASE U AS...
Page 22: ...20 6 TUB ASSY...
Page 24: ...22 7 DUCT B AS DUCT PIPE AS...
Page 78: ...76 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor...
Page 80: ...78 8 WIRING DIAGRAM...