51
5. Error reporting function
5-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
①
In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
5-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
①
In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
5-3. UE (Unbalance Error)
1) Conditions of Occurrence
①
In case main spin-drying is not reached within 20 cycles of balance spin-drying
②
In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the next
process.
2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and
pressing start/ temporary stop button. Then, spin-drying begins again.
Summary of Contents for KUD-UD122RF
Page 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 UD123X SERIES...
Page 12: ...10 1 PANEL F AS 2 UD124X SERIES...
Page 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15...
Page 18: ...16 4 CABINET ASSY...
Page 20: ...18 5 BASE U AS...
Page 22: ...20 6 TUB ASSY...
Page 24: ...22 7 DUCT B AS DUCT PIPE AS...
Page 78: ...76 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor...
Page 80: ...78 8 WIRING DIAGRAM...