41
3) Fan motor and turn table stop rotating
4) the oven lamp turns off.
5) As soon as the door is opened, the interlock monitor switch contacts close and creates the short circuit.
6) If the contacts of primary interlock switch malfunction the 20A fuse blows open due to the large current surge
caused by the short circuit activation, and this in turn stops magnetron oscillation.
5. When the CANCEL/OFF pad is touched during cooking.
1) The touch control circuit the voltage supplied to the RELAY 1 coil and causes the magnetron to stop oscillating.
2) RELAY 2 and 4 turns off.
3) The display will show the time of day. If you don’t set the clock, the display will show a colon.
4) The oven lamp turns off.
5) Fan motor and turn table motor stop rotating.
POWER LEVEL
OUTPUT POWER
RELAY 1 TURN ON, OFF TIME
AGAINST FULL POWER
P-0
0/29(0%)
P-10
3/29(10%)
P-20
5/29(17%)
P-30
8/29(28%)
P-40
11/29(38%)
P-50
14/29(48%)
P-60
17/29(59%)
P-70
20/29(69%)
P-80
23/29(79%)
P-90
26/29(90%)
P-HI
29/29(100%)
Summary of Contents for KOT-1G1A
Page 8: ...7 FIG 1...
Page 39: ...38 WIRING DIAGRAM 1 WIRING DIAGRAM...
Page 49: ...48 MP1 MP2 3 PRINTED CIRCUIT BOARD FILM...
Page 50: ...49 4 PCB CIRCUIT DIAGRAM...
Page 54: ...53 3 TOTAL ASSEMBLY KOT 1G1A...