26
19. REPLACING THE MAGNETRON
1. Remove the microwave oven from its mounting location.
2. Remove the vent grille and the cabinet from the microwave oven (See Cabinet Removal, FIG.1).
4. Remove the case blow fan top, the vent motor, the case blow fan under and the airguide top. (See Fig.5)
5. Discharge the high-voltage capacitor.
6. Unplug the red wire connectors from the high voltage transformer and the 2 screws from the magretran thermostat.
7. Remove the mounting screw from the magnetron.
FIG. 18
WARNING :
Personal Injury Hazard
Disconnect from the electrical supply before servicing the unit. Failure to do so could result in electrical shock or
other personal injury.
CAUTION :
Personal Injury Hazard
Because of the weight and size of the microwave oven, two people are required to safely move and install it.
Failure to do so could result in personal injury.
WARNING :
Personal Injury Hazard
Disconnect from the power supply, before servicing. Discharge the capacitor using a 20,000 W discharge
resistor, or an insulated plastic-handle screwdriver to short across the capacitor terminals.