
34
Cavity Thermal Cut Out
Bottom Thermal Cut Out
Vent Thermostat
Magnetron Thermostat
Open (°F/°C)
212 / 100
203 / 95
104 / 40
320 / 160
Reset (°F/°C)
140 / 60
32 / 0
132.8 / 56
239 / 115
3. COMPONENT TEST PROCEDURE
THE THERMOSTAT AND THERMAL CUT OUT
There are Two thermostats and Two Thermal Cut Out in the OTR Microwave Oven. They are the cavity thermal cut out
and the bottom thermal cut out. The cavity thermal cut out is located air guide top. This thermal cut out is “normally-
closed”, and will open at a set temperature to disable the oven.
The bottom thermal cut out is located directly behind the control panel. It is a “normally-closed”, and will open at a set
temperature to disable the oven.
The vent thermostat is located directly behind the control panel. It is a “normally-open”, that when closed, the Vent motor
activates a low speed. This thermostat is automatically resettable.
POSSIBLE CUSTOMER COMPLAINT:
The unit turns on by itself.
Summary of Contents for KOT-1G1A
Page 8: ...7 FIG 1...
Page 39: ...38 WIRING DIAGRAM 1 WIRING DIAGRAM...
Page 49: ...48 MP1 MP2 3 PRINTED CIRCUIT BOARD FILM...
Page 50: ...49 4 PCB CIRCUIT DIAGRAM...
Page 54: ...53 3 TOTAL ASSEMBLY KOT 1G1A...