36
COMPONET
TEST PROCEDURE
RESULT
Switches (with wire leads removed). All of the switches
are measured in the same manner.
Blower Motor (with leads disconnected)
Turn Table Motor (with leads disconnected)
N. O. and C Terminals
Set the ohmmeter to the R X 1
scale, and measure the resistance
between the normally-open (N.O.)
and the common (C) terminals of the
switch.
N. C. and C Terminals
Set the ohmmeter to the R X 1
scale, and measure the resistance
between the normally-close (N.C.)
and the common (C) terminals of the
switch.
Set the ohmmeter to the R x 1 scale,
and measure the:
a) High speed windings
(blue and black wires)
b) Low speed windings
(blue and white wires)
Set the ohmmeter to the R x 1000
Scale, and measure the resistance
between the motor terminals.
a) Normal - The meter
indicates infinity.
b) Abnormal - The
meter indicates zero
ohms (a short).
a) Abnormal - The
meter indicates
infinity.
b) Normal - The meter
indicates zero ohms
(a short).
a) Normal - High speed
: 25 to 45 ohms
b) Normal - Low speed
: 55 to 75 ohms
a) Normal - 2k to 4k
ohms
b) Abnormal - infinite or
zero ohms
Summary of Contents for KOT-1G1A
Page 8: ...7 FIG 1...
Page 39: ...38 WIRING DIAGRAM 1 WIRING DIAGRAM...
Page 49: ...48 MP1 MP2 3 PRINTED CIRCUIT BOARD FILM...
Page 50: ...49 4 PCB CIRCUIT DIAGRAM...
Page 54: ...53 3 TOTAL ASSEMBLY KOT 1G1A...