12
5. REPLACING THE VENT MOTOR CAPACITOR
1. Remove the microwave oven from the microwave oven location.
2. Remove the vent grille and cabinet from the microwave oven (See Cabinet Removal).
Refer to FIG.6 and Perform it as following steps
3. Remove the power cord (See the replacing the powercord, FIG. 14).
4. Remove the screw(1) and lift out the case blow fan top.
5. Remove the 2 screws(2) for the vent motor and remove the vent motor.
6. Remove the screw(3) and lift out the case blow fan under.
7. Remove the screw(4) and lift out the air guide top.
8. Disconnect the two wire connectors from the vent motor capacitor terminals.
9. Reconnect the wires to the new vent motor capacitor terminals, as shown in the FIG.5.
10. Reinstall all the removed components carefully on the microwave oven.
WARNING :
Personal Injury Hazard
Disconnect from the electrical supply before srvicing the unit. Failure to do so could result shock or other
personal injury.
FIG. 5
CAUTION :
Personal Injury Hazard
Because of the weight and size of the microwave oven, two people are required to safely move and install it.
Failure to do so could result in personal injury.