28
OPERATION AND FUNCTIONS
10. Forced
11. Initial Defrosting
12. Buzzer or Alarm
Defrosting
INPUT
Control Object
1. "FRZ. SET" Button
2. "REF. SET." button
3. "LOCK" button
Defrosting Mode
CONTENTS
REMARKS
1. How to start
Set "LOCK ON" first, then push "REF. SET" button 5 times
while pushing "FRZ. SET" button simultaneously.
2. How to proceed
1) Delete Pre-cool mode. (Others are same as normal defrosting.)
2) Heater is ON regardless of D-sensor temp. at first 30 seconds.
( Check of defrosting current)
INPUT
Control Object
D-sensor
Initial or first power input (power plugin)
Defrosting Mode
CONTENTS
REMARKS
If D-sensor temp.
3.5
, defrosting mode starts from Pre-cool at first
power input.
Comp. is delayed for 6 min.
at the initial defrosting.
INPUT
Control Object
F-PCB buttons
Door Switch
Initial Power Input
BUZZER
CONTENTS
REMARKS
1. Buzzer sounds if any button of F-PCB is pushed.
2. Buzzer sounds 4 times, 3 seconds after initial power input.
3. Buzzer sounds 3 times in case of A/S forced defrosting, 1 time
in case of Pull Down operation.
4. If door is open, buzzer sounds every 1 minute for 5 minutes.
(Door open alarm)
13. LCD Background Light
INPUT
Control Object
F-PCB buttons
Door Switch
Initial Power Input
LCD BACK LIGHT
C
Summary of Contents for FRS-T20BA Series
Page 1: ...FRST20BA00...
Page 3: ...1 EXTERNAL VIEWS 1 1 EXTERNAL SIZE 3...
Page 4: ...4...
Page 5: ...5...
Page 6: ...6...
Page 35: ...33 OPERATION AND FUNCTIONS 21 Refrigeration Cycle...
Page 36: ...34 OPERATION AND FUNCTIONS 22 Cold Air Circulation...
Page 37: ...35 DIAGRAM 4 Wiring DIAGRAM 1 RSCR Type Wiring Diagram...
Page 38: ...36 DIAGRAM 2 CSR Type Wiring Diagram...
Page 39: ...37 DIAGRAM 3 CIRCUIT WIRING DIAGRAM 1 Main PCB...
Page 40: ...38 DIAGRAM 2 FRONT PCB DIAGRRAM...
Page 47: ...CABINET 45 6 1 FRS T20BA FRS T24BA 6 EXPLODED VIEW...
Page 48: ...EXPLODED VIEW MECH ROOM 46...
Page 49: ...EXPLODED VIEW R Room 47...
Page 50: ...48 EXPLODED VIEW F ROOM...
Page 51: ...49 EXPLODED VIEW F Door...
Page 52: ...50 EXPLODED VIEW R Door...
Page 59: ...CABINET 57 6 3 FRS T20HA FRS T24HA 6 EXPLODED VIEW...
Page 60: ...EXPLODED VIEW MECH ROOM 58...
Page 61: ...EXPLODED VIEW R Room 59...
Page 62: ...60 EXPLODED VIEW F ROOM...
Page 63: ...61 EXPLODED VIEW F Door...
Page 64: ...62 EXPLODED VIEW R Door...