29
OPERATION AND FUCTIONS
CONTENTS
REMARKS
1. Conditions to turn on LCD Light
1) Power input (plugin)
2) When any button on the panel is pushed, first the back light turns on, then
button control is done.
3) When F/R door is open, the light turns on.
2. Conditions to turn off the light
1) The back light turns off 10 seconds after F/R door is closed
2) 1 minute after button control
14. Explanation After Delivery
INPUT
Control Object
"FRZ. SET" button
"REF. SET" button
Power Cord
Electrical components and LCD
CONTENTS
REMARKS
1. Start
Push "REFRIGERATOR SET." button for 3 seconds within 10 seconds just
after power input.
2. Control
1) Electrical components are OFF for 3 hours.
2) Display operates in normal way.
15. Prevention of Compressor Restart
INPUT
Control Object
None
Comp.
CONTENTS
REMARKS
Comp. does not start again for 6 minutes though F-sensor is ON.
6min. delay
Summary of Contents for FRS-T20BA Series
Page 1: ...FRST20BA00...
Page 3: ...1 EXTERNAL VIEWS 1 1 EXTERNAL SIZE 3...
Page 4: ...4...
Page 5: ...5...
Page 6: ...6...
Page 35: ...33 OPERATION AND FUNCTIONS 21 Refrigeration Cycle...
Page 36: ...34 OPERATION AND FUNCTIONS 22 Cold Air Circulation...
Page 37: ...35 DIAGRAM 4 Wiring DIAGRAM 1 RSCR Type Wiring Diagram...
Page 38: ...36 DIAGRAM 2 CSR Type Wiring Diagram...
Page 39: ...37 DIAGRAM 3 CIRCUIT WIRING DIAGRAM 1 Main PCB...
Page 40: ...38 DIAGRAM 2 FRONT PCB DIAGRRAM...
Page 47: ...CABINET 45 6 1 FRS T20BA FRS T24BA 6 EXPLODED VIEW...
Page 48: ...EXPLODED VIEW MECH ROOM 46...
Page 49: ...EXPLODED VIEW R Room 47...
Page 50: ...48 EXPLODED VIEW F ROOM...
Page 51: ...49 EXPLODED VIEW F Door...
Page 52: ...50 EXPLODED VIEW R Door...
Page 59: ...CABINET 57 6 3 FRS T20HA FRS T24HA 6 EXPLODED VIEW...
Page 60: ...EXPLODED VIEW MECH ROOM 58...
Page 61: ...EXPLODED VIEW R Room 59...
Page 62: ...60 EXPLODED VIEW F ROOM...
Page 63: ...61 EXPLODED VIEW F Door...
Page 64: ...62 EXPLODED VIEW R Door...