3. Control Time Chart of Each Mode
1) Start & stop of load control mode (Normal Control)
Door
F/S
F Fan
R/S
R Fan
Door Open
30s after Door
Open
Load Mode Start
Ref. Load stop
Frz. Load stop
On + 5deg
On + 5deg
Frz. Overload Input
Frz. Start Condition
Frz. Stop ; after 20min.
20min.
20min.
Ref. Load
14V
14V
12V
12V
2) Start & stop of load control mode (Silence Control)
Door
F/S
F Fan
R/S
R Fan
Door Open
30sec. after open
Load Mode Start
Ref. Load Stop
Frz. Load Stop
On + 5deg
On + 5deg
Frz. Overload Input
Frz. Load Start
Frz. Stop Condition ;
after 20min.
20min.
20min.
Ref. Load
12V
12V
10V
8V
3) Start & stop of load control mode (Normal defrosting control)
F /S
F F a n
R /S
R F a n
D e f ro s t in g S ta rt
C o n d it io n t o s ta rt L o a d
M o d e , b u t a v o i d e d
b u rin g d e f ro s t in g m o d e
R e f . L o a d S t o p
O n + 5 d e g
N o rm a l O p e ra ti o n
2 0 m in .
R e f . L o a d M o d e
1 4 V
1 2 V
8 V
H T R
C o m p
Summary of Contents for FRS-T20BA Series
Page 1: ...FRST20BA00...
Page 3: ...1 EXTERNAL VIEWS 1 1 EXTERNAL SIZE 3...
Page 4: ...4...
Page 5: ...5...
Page 6: ...6...
Page 35: ...33 OPERATION AND FUNCTIONS 21 Refrigeration Cycle...
Page 36: ...34 OPERATION AND FUNCTIONS 22 Cold Air Circulation...
Page 37: ...35 DIAGRAM 4 Wiring DIAGRAM 1 RSCR Type Wiring Diagram...
Page 38: ...36 DIAGRAM 2 CSR Type Wiring Diagram...
Page 39: ...37 DIAGRAM 3 CIRCUIT WIRING DIAGRAM 1 Main PCB...
Page 40: ...38 DIAGRAM 2 FRONT PCB DIAGRRAM...
Page 47: ...CABINET 45 6 1 FRS T20BA FRS T24BA 6 EXPLODED VIEW...
Page 48: ...EXPLODED VIEW MECH ROOM 46...
Page 49: ...EXPLODED VIEW R Room 47...
Page 50: ...48 EXPLODED VIEW F ROOM...
Page 51: ...49 EXPLODED VIEW F Door...
Page 52: ...50 EXPLODED VIEW R Door...
Page 59: ...CABINET 57 6 3 FRS T20HA FRS T24HA 6 EXPLODED VIEW...
Page 60: ...EXPLODED VIEW MECH ROOM 58...
Page 61: ...EXPLODED VIEW R Room 59...
Page 62: ...60 EXPLODED VIEW F ROOM...
Page 63: ...61 EXPLODED VIEW F Door...
Page 64: ...62 EXPLODED VIEW R Door...