Caution :
The injection lines are designed for high operating pressures and should thus be handled
with particular care.
•
When mounting the pipes to the engine take care of good fitness.
•
Do not bend pipes to permanent deformation (not for replacing the nozzles either).
•
Do not mount any heavily bent pipes.
•
Avoid bending the pipes at the ends by more than 2 to 3 degrees.
In case of faults in the injection system which might have resulted in excessive operating pressures,
not only the failed part but also the injection line has to be replaced.