4.3.5. DE12TIS fuel injection pump inspec-
tion & adjustment only
1)
Pre-stroke actuator inspection drive
shaft.
Replace the drive shaft if the ball section
is bent,worn or damaged.
- 121 -
EA2M4002
2) Electrical components
(1) Check the resistances between the
prestroke actuator terminals shown in
the figure at left using a circuit tester.
Their resistances are shown below.
Also, check that the resistance
between the terminals and the hous-
ing is
∞
.
Terminal
Resistance(
Ω
)
1~2
2.45~2.95
3~4
5.5~6.1
5~6
5.5~6.1
EA2M4003
(2) Check the conductance between
each of the pre-stroke acuator termi-
nals and connectors using a circuit
tester.
COUTION : The connector ter-
minal layouts and
shapes differ with
maker and engine.
Con.
Act.
Harness
term
term
Remarks
no
no
color
1
6
Green
Act drive(-)
2
5
Yellow
Act drive(+)
3
4
Black/White
Shield
4
3
Black
P/s sen(GND)
5
2
White
P/s sen(MDL)
6
1
Blue
P/s sen(OSC)
EA2M4004