-9-
Service Manual CP-099F
Special case : GB
Note for setellite receiver users : Before starting
ATSS turn On your satellite receiver and tune “ SKY NEWS ”.
If GB is selected the TV controlling software seeks for programs only in UHF ( C21 to C70 ).
The sorting order is :
1 - BBC1
2 - BBC2
3 - ITV
4 - CH4
5 - CH5
6 - NEWS
If two or more “ identical” progr ams ( same name but different code e.g. BBC1 and BBC1 Scotland ) are found
the f ollowing programs in the list will be shifted up. (1 - BBC1, 2 - BBC1, 3 - BBC2, 4 -ITV, 5 - CH4, 6 - CH5,
7 - NEWS, ..)
If one of the program above is not found, the associated program number remains empty
( freq.=467.25 Mhz - Skip selected - no name - system=GB).
example A : 1 - BBC1, 2 - BBC2, 3 - ITV , 4 - ----, 5 - CH5, 6 - NEW S , ...
example B ( if 2 BBC1 found ) : 1 - BBC1, 2 - BBC1, 3 - BBC2, 4 - IT V, 5 - -----, 6 - CH5, 7 -NEWS, ...
2 - Safety instruction
WARNING: Only competent service personnel may carry out work involving the testing or repair of this equipment.
X-RAY RADIATION PRECAUTION
1. Excessive high voltage can produce potentially hazardous X-RAY RADIATION. To avoid such hazards, the high
voltage must not exceed the specified limit. The nominal value of the high voltage of this receiver is
27.5 KV (21”) at max beam current. The high voltage must not, under any circumstances.
exceed 31 KV (21"). Each time a receiver requires servicing, the high voltage should be checked.
It is important to use an accurate and reliable high voltage meter.
2. The only source of X-RAY Radiation in this TV receiver is the picture tube. For continued X-RAY RADIATION
protection, the replacement tube must be exactly the same type tube as specified in the parts list.
SAFETY PRECAUTION
1. Potentials of high voltage are present when this receiver is operating. Operation of the receiver outside the cabinet
or with the back board removed involves a shock hazard from the receiver.
1) Servicing should not be attempted by anyone who is not thoroughly familiar with the precautions necessary
when working on high voltage equipment.
2) Discharge the high potential of the picture tube before handling the tube. The picture tube is highly evacuated
and if broken, glass fragments will be violently expelled.
2. If any Fuse in this TV receiver is blown, replace it with the FUSE specified in the Replacement Parts List.
3. When replacing a high wattage resistor ( metal oxide film resistor) in the circuit board, keep the resistor
10 mm away from circuit board.
4. Keep wires away from high voltage or high temperature components.
5. This receiver must operate under AC 230 volts, 5O Hz. NEVER connect to DC supply or any other power or
frequency.
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in this equipment have special safety-related characteristics.
These characteristics are often passed unnoticed by a visual inspection and the X-RAY RADIATION protection
afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage,
wattage, etc. Replacement parts which have these special safety characteristics are identified in this manual and its
supplements, electrical components having such features are identified by designated symbol on the parts list.
Before replacing any of these components, read the parts list in this manual carefully. The use of substitutes
replacement parts which do not have the same safety characteristics as specified in the parts list may create X-RAY
Radiation.
Summary of Contents for DDT-21H9ZZF
Page 17: ...16 Service Manual CP 099F...
Page 36: ...Service Manual CP 099F 35 5 Circuit desription 5 1 Block diagram...
Page 60: ...Service Manual CP 099F 59 5 11 3 SCHEMATIC DIAGRAM 5 11 3 1 AUDIO...
Page 61: ...Service Manual CP 099F 60 5 11 3 2 DRIVE RF...
Page 62: ...Service Manual CP 099F 61 5 11 3 3 DSP...
Page 63: ...Service Manual CP 099F 62 5 11 3 4 MICOM...
Page 64: ...Service Manual CP 099F 63 5 11 3 5 MPEG...
Page 77: ...Service Manual CP 099F 76 9 PRINTED CIRCUIT BOARD 9 1 DVD PCB The upper...
Page 78: ...Service Manual CP 099F 9 2 DVD PCB The lower 77...
Page 79: ...Service Manual CP 099F 9 3 POWER PCB 78...
Page 80: ...Service Manual CP 099F 9 4 MAIN PCB 79...
Page 81: ...80 Service Manual CP 099F 10 SCHEMATIC DIAGRAM 10 1 POWER CRT...
Page 82: ...81 Service Manual CP 099F 10 SCHEMATIC DIAGRAM 10 2 PCB MAIN...