3.5 During the cleaning, the distance between the nozzle and the object surface to be cleaned should
not be too far, normally not more than 30cm, as the impulsive force decreases with the increase of the
distance.
*. You should hold the gun trigger firmly during the cleaning.
*. The safety value doesn’t control the gun during operation, but only prevents it from opening uninten-
tionally.
*. Spraying the human beings or electric equipment is forbidden.
*. Don’t place the power wire on the road so as to avoid breaking the wire.
*. The nozzles used in the cleaner are supplied by our factory.
3.6 After the cleaning is finished, open the trigger, switch off the pump and unplug the power cable from
the mains. Close the water inlet and detach the appliance from the water connection. Pull the trigger
until there is no more pressure in the appliance, and secured the trigger with safety button against
unintentional opening.
3.7 After operating ,you may put the lance and the trigger gun into the gun holder.
3.8 Wires can be winded evenly on the wire hook after using. Wire hook can be rotated 360 degree, for
the convenience of removing wires in next use.
5. MAINTENANCE
1. Monthly or as required, maintenance the appliance
1.1 Clean the nozzle. Remove dirt from the nozzle hole with a needle and rinse it with water from the
front.
1.2 Clean the strainer in the water connection. It can be easily removed with flat-nosed pliers.
2. Winter protection
Frost will destroy an appliance that has not been completely emptied of water. The correct method is to
separate the inlet hose from the water supply system. Turn on the cleaner to run for about 30 seconds
for water extraction. Remove the high-pressure plastic hose to exhaust the remaining water in it. The
appliance had better be stored in a warm room.
EN