86
Periodical check
SYSTEM NO
Check list
Working
Standard
everyday every every every
every Replace
Remarks
or at any 100
200
1
2
period
time
hrs.
hrs. season season
22 Suction &
Check
No cooling
●
discharge V/A
23 Compressor
1500hrs
24 Compressor
Jointing
Looseness
●
mounting
25 Evaporator fin
Cleaning
Dirty
●
26 Fixing part of
Jointing
Looseness
●
evaporator fan
27 Operation of
Check
Noise
●
1500hr
evaporator fan
28 Fan belt
Check
Wound
replace
aging,
●
2 seasons
tension
29 Unit fixing bolt
Jointing
Looseness
●
30 Viberation
Check
●
2 seasons
protector(rubber)
31 Cool air leakage Check
Sight check
●
32 Duct insulator
Check
Aging
●
Disassemble & clean at
every 4 seasons or 500hrs.
Prohibit a steam seshing
5mm is push down
at 5Kg/force press
Compressor
Cooler
box
Connecting
system
Others