Water Filter Performance Data
Interior Water Filtration System
Model AFF3 (67003523-750) Capacity 750 Gallons (2839 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permis-
sible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class I*
50% reduction
85% reduction
2.00 mg/L
14,000,000 #/mL
2.0 mg/L ± 10% At least
10,000 particles/mL
0.06 mg/L
370,000 #/mL**
0.050625 mg/L
196,666 #/mL
97.00%
97.40%
97.52%
99.00%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L
0.010 mg/L
0.150 mg/L†
0.150 mg/L†
0.15 mg/L ± 10%
0.15 mg/L ± 10%
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
>99.30%
>99.30%
>99.30%
>99.30%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.006 mg/L
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0005 mg/L
0.0018 mg/L
0.0003 mg/L
0.00073 mg/L
91.70%
69.20%
95.00%
88.10%
Benzene
0.005 mg/L
0.0133 mg/L
0.015 mg/L ± 10%
0.0005 mg/L
0.0005 mg/L
96.10%
96.30%
p-Dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L ± 10%
< 0.0005 mg/L
< 0.0005 mg/L
>99.80%
>99.80%
Carbofuran
0.040 mg/L
0.0753 mg/L
0.08 mg/L ± 10%
0.027 mg/L
0.008 mg/L
64.60%
73.45%
Toxaphene
0.003 mg/L
0.015 mg/L
0.15 ± 10%
< 0.001mg/L
< 0.001mg/L
93.3%
93.3%
Atrazine
0.003 mg/L
0.0102mg/L
0.009 mg/L ± 10%
< 0.0027mg/L
< 0.00105mg/L
76.30%
89.40%
Asbestos
>99%
126.5 MF/L
107 to 108 fibers/L††
< 0.17 MF/L
< 0.17 MF/L
>99.99%
>99.99%
Live Cysts‡
Turbidity
>99.95%
0.5 NTU
122,500 #/L
10.5 NTU
50,000/L min.
11 ± 1 NTU
< 1 #/L‡
0.30 NTU
< 1 #/L‡
0.125 NTU
>99.99%
97.30%
>99.99
98.80%
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 ± 10%
< 0.00016mg/L
0.000035mg/L
91.80%
97.90%
Tetrachloroethylene
0.005 mg/L
0.015 mg/L
0.015 mg/L ± 10%
< 0.0005 mg/L
< 0.0005 mg/L
>96.6%
>96.6%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm).
Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F (20°C ± 3°C).
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust
†
These contaminants are not necessarily in your water supply. Performance may vary
based on local water conditions
††
Fibers greater than 10 um in length
‡
Based on the use of Cryptosporidium parvum oocysts
Specifications
Water Supply:
City or well
Service Flow Rate:
.78 gpm (2.9 L/min) @ 60 psi
Water Pressure:
35 - 120 psi (241 - 827 kPa)
Water Temperature:
33° - 100°F (1° - 38°C)
It is essential that operational, maintenance and filter replacement
requirements be carried out for the product to perform as adver-
tised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter’s rated life is used, the order light comes
on. When 100% of the filter’s rated life is used, the replace light
comes on, and it is recommended that you replace the filter.
For models without filter status lights, replace the filter every 6
months. Use Dacor replacement cartridge AFF3.
This product is for cold water use only.
System tested and certified by NSF
®
International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and
Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
p-Dichlorobenzene, Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the