11
L1
N1
Gnd
L1
N1
Gnd
Installation Instructions
Example of Installation with Bottom Exhaust
(Side View)
REMP Series
Remote Blower
Outside Wall
Wires from power conduit.
Connect other end of wires to
“Blower Output” inside ERV
electrical access panel
Match wire colors to
terminals as shown
Floor
ERV
ER36D or
ER48D Range
Power conduit from ERV
to remote blower
Remote Blower
Terminal Block
Remote Blower
Wiring
See ERV electrical
access panel on
facing page
BLACK
WHITE
GREEN
Range Installation
Install the range according to the range installation instructions.
Once the range is installed, make sure that the top cap on the raised vent intake does not
catch on the back edge of the range when the intake is lowered.
If interference does occur, adjust the position of the range by moving it against the front
edge of the countertop cutout.
Make sure the vent anchoring legs are properly secured to the cabinet base with the sup-
plied wood screws. Failure to eliminate any interference may result in permanent damage
to the vent.