Important Safety Instructions

Do not install or operate this unit if it has been 

1. 

damaged, dropped, has damaged electrical wiring 

or is not working properly. If the product is damaged 

when received, immediately contact the dealer or 

builder.
Use this raised vent only for its intended purpose 

2. 

as outlined in the use and care manual. Do not use 

this unit to vent hazardous or explosive materials 

or vapors. This appliance is not intended for 

commercial use.
The customer should not install, repair or 

3. 

replace any part of this unit unless specifically 

recommended in the literature accompanying it. A 

qualified service technician should perform all other 

service. Contact the Dacor Customer Service Team 

for examination, repair or adjustment.
Keep all packaging materials away from children. 

4. 

Plastic bags can cause suffocation.
This raised vent must be installed and grounded by 

5. 

a qualified installer according to these installation 

instructions. All installation work and electrical 

wiring must be performed in accordance with all 

applicable codes and standards, including fire-rated 

construction.
Install or locate this appliance only in accordance 

6. 

with these installation instructions and the Dacor 

range installation instructions. Improper installation, 

adjustment, alteration, service or maintenance can 

cause serious personal injury or property damage.
Sufficient air is needed for proper combustion and 

7. 

exhausting of gases through the flue (chimney) of 

fuel burning equipment to prevent back drafting. 

Follow the heating equipment manufacturer’s 

guidelines and safety standards such as those 

published by the National Fire Protection 

Association (NFPA), and the American Society 

for Heating, Refrigeration and Air Conditioning 

Engineers (ASHRAE) and the local code 

authorities.
When cutting or drilling into the wall or ceiling, 

8. 

do not damage electrical wiring and other hidden 

utilities.
Always vent ducted fans to the outdoors. Do not 

9. 

vent exhaust air into spaces within walls or ceilings 

or into attics, crawl spaces or garages.
Before installing or servicing the raised vent, 

10. 

disconnect the power plug from the electrical outlet.

 WARNING

General Safety Precautions

To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precau-

tions, including the following:

To reduce the risk of electric shock or fire connect 

11. 

remote blowers with a total combined current draw 

of eight (8) amps or less. 
The installer must show the customer the location 

12. 

of the electrical outlet so that the customer knows 

where and how to disconnect power.
Read the use and care manual completely before 

13. 

using this raised vent.
Do not tamper with the controls.

14. 

Never allow the filters or vent openings to become 

15. 

blocked or clogged. Do not allow foreign objects, 

such as cigarettes or napkins, to be sucked into the 

vent holes.
Clean the filters and all grease-laden surfaces often 

16. 

to prevent grease fires and maintain performance. 

Clean this appliance only as specified in the use 

and care manual.
Do not leave children or pets alone or unattended in 

17. 

the area around the range when it is in use. Never 

allow children to sit or stand on an appliance. Do 

not let children play with a range or the raised vent. 

Do not store items of interest to children above or 

around the range.
Install this raised vent only with Dacor ER36D and 

18. 

ER48D series ranges.
This appliance is equipped with a three-prong 

19. 

grounding plug for your protection against possible 

electric shock hazards. It must be plugged into 

a dedicated, grounded electrical outlet. Where a 

standard two-prong wall receptacle is encountered, 

it is the personal responsibility and obligation of 

the customer to have it replaced with a dedicated, 

properly grounded three-prong wall receptacle. Do 

not under any circumstances:

Cut or remove the 

• 

third (ground) prong 

from the power cord. 
Use an adapter plug. 

• 

Use an extension 

• 

cord. 
Use a power cord that 

• 

is frayed or damaged.
Use of a ground fault 

• 

interrupter (GFI) is not 

recommended.

 WARNING

Summary of Contents for ERV36-ER

Page 1: ...Installation Instructions Downdraft Raised Vent Models ERV36 ER ERV48 ER Part No 103106 Rev C These downdraft vents are designed for use with Dacor ER36D and ER48D series ranges...

Page 2: ...ications Tested in accordance with the latest edition of ANSI Z 21 1 standard for household gas cooking appliances ANSI UL 858 household electrical ranges CAN CSA C22 2 NO 64 Standard for Household El...

Page 3: ...You Need Help 3 Appliance Data Plate 3 Product Specifications 3 Product Dimensions 3 Important Safety Instructions Important Installer In the interest of safety and to minimize problems read these ins...

Page 4: ...o the outdoors Do not 9 vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Before installing or servicing the raised vent 10 disconnect the power plug from th...

Page 5: ...ce Information Product Specifications Appliance Data Plate The appliance data label also specifies the power supply requirements Model Identification ERV36 ER 36 Inch Raised Vent ERV48 ER 48 Inch Rais...

Page 6: ...ld be installed only by a licensed electrician Electrical Specifications The raised vent is supplied with a 28 711 mm power cord terminated by a three prong plug Plug it directly into a dedicated grou...

Page 7: ...Number ERV Cutout Width C Range Cutout Width D Min ERV36 ER 33 1 2 848 mm 36 1 16 916 mm ERV48 ER 43 1 2 1102 mm 48 1 16 1221 mm Depth dimensions are at the discretion of the customer For reference d...

Page 8: ...ure to duct air outside the house or building Do not vent exhaust air into spaces within walls or ceil ings or into attics crawl spaces or garages Tape all duct joints securely to prevent combus tion...

Page 9: ...elbows and tran sitions used The equivalent number of feet for each elbow and transition must be subtracted from the maxi mum straight length to compensate for wind resistance 3 1 4 x 10 90 Elbow 3 1...

Page 10: ...ons on page 4 do not proceed with the installation Call a licensed electrician and have an electrical outlet installed that meets the specifications Install the vent only in a vertical orientation Do...

Page 11: ...attach the anchoring legs to the studs on the 5 left and right sides of the raised vent using the provided hex nuts and washers Place the vent into the rear of the countertop cutout 6 with the electri...

Page 12: ...BLACK WHITE GREEN Electrical Installation warning ELECTRIC SHOCK HAZARD Do not connect power to the unit until installation is complete Run the conduit line used to supply power from the 1 raised vent...

Page 13: ...e ERV electrical access panel on facing page BLACK WHITE GREEN Range Installation Install the range according to the range installation instructions Once the range is installed make sure that the top...

Page 14: ...d control switch counter clockwise to hi speed and clockwise to low speed Press the top cap up down switch once to lower the 5 vent Installation Checklist Are the anchor legs extended down to make con...

Page 15: ......

Page 16: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...