Planning the Installation
System Layout
The vent system consists of the raised vent itself and a
•
remote blower. You must install a Dacor model REMP3
or REMP16 remote blower for the raised vent to oper-
ate properly. For directions on installing the remote
blower, see the REMP3/16 installation instructions.
WARNING
Failure to install a remote blower or proper duct
•
work may result in a back draft and/or the insufficient
venting of smoke and fumes.
To reduce the risk of personal injury caused by
•
reaching over a hot appliance, cabinet storage
space located directly above the range should be
avoided.
Do not store combustible materials or items adverse-
•
ly affected by heat in cabinet areas above the appli-
ance.
Follow the instructions and diagrams for minimum
•
safe clearances and installation location. Failure to
do so may result in a fire or safety hazard.
Wire the remote blower to turn on when the raised vent
•
is turned on by running a piece of conduit parallel to
the duct work and connecting it to the raised vent on
one end and the remote blower on the other. There are
7/8” access holes in the bottom and side of the raised
vent for connecting the conduit.
The raised vent exhaust may be configured to vent
•
through the back, the bottom or through one of the
sides. The maximum allowable duct run must be taken
into consideration when determining the layout. See
Planning the Duct Work
for further details.
WARNING
Observe all governing codes and ordinances during
•
planning and installation. Contact your local building
department for further information.
The electric outlet for the raised vent should be
•
installed only by a licensed electrician.
Electrical Specifications
The raised vent is supplied with a 28” (711 mm) power
cord terminated by a three-prong plug. Plug it directly into a
dedicated, grounded, three prong, electrical outlet. Do not
use an extension cord.
The correct voltage, frequency and amperage must be sup-
plied to the electrical outlet from a grounded, single phase
circuit that is protected by a properly sized circuit breaker
or time-delay fuse.
Electrical Supply Requirements
A 3 prong electrical outlet connected to a 120 Vac, 60
•
Hz, 15 Amp. grounded, dedicated circuit is required.
The customer must supply conduit with minimum
•
current carrying capacity of 8 Amps to supply power
to the remote blower from the raised vent. See
Planning the Duct Work
for further details.
The above specifications are for reference only. If the
•
power supply requirements shown above do not agree
with those listed on the appliance data label, use the
required voltage, frequency and amperage ratings on
the appliance data label.
It is the owner’s responsibility to ensure that electrical
•
outlet is installed by a licensed electrician. The electri-
cal installation must comply with the latest revision of
the National Electric Code ANSI/NFPA 70 (latest revi-
sion) and local codes and ordinances.
If the electrical service provided does not meet the
•
product specification, or does not conform to the NEC
or local standards, do not proceed with the installation.
Call a licensed electrician to correct the electrical ser-
vice before proceeding.
Locate the electrical outlet in an accessible location,
•
so that the power plug can be disconnected for service
without removing the raised vent or the range from the
cabinet.
Installation Specifications
Conduit Access Hole Locations
Vent shown in
down position
Side
Bottom