![dacell DN520N Instruction Manual Download Page 32](http://html1.mh-extra.com/html/dacell/dn520n/dn520n_instruction-manual_3129428032.webp)
PAGE
31
/
53
Serial Printer Setting
Weight Unit selection (Printer)
F50
●
0
kg
1
g
2
t
AUTO Print Selection
F51
●
0
When weight reached Empty Range(F80 set value), Automatically
print.
- Check Empty Range
1
Over than Empty Range, Steady Lamp is “ON”, Automatically Print.
- Will not check Empty Range
Print Format selection
F52
●
0
Continuous Print
Serial No. and Weight will be printed continuously.
1
Single Print
Date, Time, S/N, ID No. Weighing Data will be print
SUB/GRAND Total Data Delete selection
F53
●
0
Manual Delete Mode
SUN Total Delete :
“Clear” key + “SUB” key
GRAND Total Delete : “Clear” key + “GRAND” key
1
Automatic Delete Mode
After SUB/GRAND Total Print, Automatically Deleted.
Paper Withdraw Rate setting (After Finish Printing process)
F54
4
0
∫
9
Whenever set value increased, 1line will be added.
Printer Line Interval Selection (Only for Continuous Printer format)
F55
1
0
∫
9
Whenever set value increased, 1line will be added.
SUB Total Print Mode Selection
F56
●
0
Normal Mode
1
Normal Mode + Average total value print