Once the update has started, the pump will show the status on the display, which will end with “Done!” and will restart immediately afterwards.
If the update is unsuccessful, the Esybox Max you were trying to update will restart with the previous software version, so you can repeat the
operation.
Software alignment between two Esybox Max devices
If a smartphone is not available (which is recommended to take advantage of the latest available update) it is possible to carry out local software
alignment between two Esybox Max devices of the same model.
The software alignment of similar products is necessary to allow the creation of the pump set.
The procedure is carried out between two Esybox Max devices at a time, in case of more than one Esybox Max to be updated the procedure
must be repeated each time.
Procedure:
Make the association between two Esybox Max devices (see 8.5.5 AS Device Association).
If the two Esybox Max devices have a different software version (which can be checked from the VE menu) they will display a popup indicating
that you are trying to make an association between two products with different firmware. The popup also indicates the firmware version and tells
you to press the ^ key.
This key can be pressed on any Esybox Max involved in the software alignment phase.
Once the update has started, the pump will show the status on the display, which will end with “Done!” and will restart immediately afterwards.
Check via the VE menu that the Esybox Max has been updated to the desired version.
If the update is unsuccessful, the Esybox Max you were trying to update will restart with the previous software version, so you can repeat the
operation.
12.3 DSYNC
DAB products with integrated DConnect feature smart solutions that help the user during the initial configuration and use of the product.
With DSync you can save time for the first configuration and software update of the Esybox Max, which will be part of a new booster set.
It will be enough to configure only one pump in the set and propagate the settings to the other pumps via the DSync function.
In greater detail, when creating a new pump set via DSync you can:
•
Update the Esybox Max devices present to the latest software version available
•
Align the language and measurement unit settings for each pump in the set
•
If you want to use the DConnect Cloud service, you can enable the service on an Esybox Max to which you are directly connected and
propagate the settings to the other pumps in the set.
Requirements:
To use the DSync function
•
The Esybox Max must not have been previously synchronised (via DSync) with other similar pumps (it is possible to restore the status
from App in the product menu).
•
It must have been powered for no more than 30 mins (otherwise just restart it)
•
If a software update is necessary, consider that it can take up to 5 minutes per pump.
Procedure:
•
Click on the “Direct connection” button
on the main page of the Dconnect App.
•
Select the image of the Esybox Max product
•
Follow the step-by-step instructions in the APP
•
Click on the green DSync button
•
The APP screen will display the number of pumps found at the installation site that can be
synchronised as they are in a “first configuration” state.
•
At the same time the displays of the Esybox Max devices involved will also flash to communicate that they are about to be
synchronised.
•
The first step is to update the software of the pumps found.
Once the update has started, the pump will show the status on the display and restart when the update is complete. On the APP a symbol with
a green check mark will confirm the operation. If not, you can repeat the operation with the appropriate symbol
•
The second phase of DSync deals with the alignment of the parameters related to the user's location (language, unit of measurement)
and any WiFi configurations and information related to the DConnect cloud service. A symbol with a green cloud will confirm the
operation.