background image

                                                                   

ENGLISH                                                

 

23 

 

− 

At suction from a well it is indispensable to 
install a foot valve complete with filter (Fig.7).

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

− 

The pump is supplied with fittings: 

1” GAS for 50Hz versions 
1” NPT for 60Hz versions (on request also GAS) 

If a fitting is also used on suction, it must be of the 
non deformable type (Fig.8) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.2  Electrical connections  

 
 

                   

ATTENTION!! 

                   ALWAYS OBSERVE THE SAFETY  
                   REGULATIONS!!  

 

Electrical installation must be carried out by an 
authorised, skilled electrician who assumes all 
responsibility.   

 
 

                   THE SYSTEM MUST BE  
                   CORRECTLY AND SAFELY 
                   EARTHED!!  

 
 

− 

Ensure that the mains voltage is the same as that  
shown on the motor data plate. 

          

        

 

 

− 

The correct operating voltage and frequency are 
indicated on the pump data plate. 

 

                    Never make any connection on the terminal
                    card if the electric power supply has not 
                    been  deactivated  for at least 5 minutes. 
                     

                   

 

  

5.3 Starting 

 

                    

DO NOT START THE PUMP WITHOUT 

                    HAVING COMPLETELY FILLED IT 
                    WITH FLUID. 

 

Before starting, check that the pump has been regularly 
primed, filling it completely with clean water through the 
hole provided, after having removed the filling cap, 
located on the pump body. The filling cap must then be 
accurately screwed back on (Fig.9). 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

− 

Connect the power cable to the mains. 

− 

When the cable is connected, the red warning light 
and the green one on the control panel light up 
simultaneously for 3 seconds (Fig.10). 
The remote alarm signal will also be activated for 3 
seconds, if present. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 10 

Fig. 8 

Foot valve 

Fig. 7 

H 2

0

Fig. 9 

Summary of Contents for ACTIVE J 62

Page 1: ...CTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONSANWEISUNG UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERH LLS...

Page 2: ...N VERPANEL KONTROL PANELI PANOU DE CONTROL XB w A R TAPPO DI CARICO BOUCHON DE REMPLISSAGE FILLING CAP F LLSCHRAUBE VULDOP TAP N DE CARGA P FYLLNINGSPLUGG DOLDURMA TIPASI CAPAC DE NC RCARE IlK A Bio T...

Page 3: ...0 6 ACTIVE E 30 30 6 ACTIVE EI 30 30 6 ACTIVE EC 30 30 6 ACTIVE E 40 30 6 ACTIVE EI 40 30 6 ACTIVE E 30 50 6 ACTIVE EI 30 50 6 ACTIVE EC 30 50 6 ACTIVE E 40 50 6 ACTIVE EI 40 50 6 ACTIVE EC 40 50 6 AC...

Page 4: ...ingen DECLARACI N DE CONFORMIDAD La empresa DAB PUMPS s p a Via Marco Polo 14 Mestrino PD ITALY bajo su propia y exclusiva responsabilidad declara que los productos Active Active System rese ados ante...

Page 5: ...against dry running 1 1 Applications Active is used particularly for increasing pressure in storage tanks and for supplying water from wells in houses in holiday homes in farms in greenhouses and gar...

Page 6: ...or pumping water containing air hydraulic technopolymer suitable for pumping water containing air silent running silent running and stainless suitable for pumping water containing air hydraulic techno...

Page 7: ...cess temperature of hydraulic parts There is the possibility of remote signalling of the alarm signal in fact on the electronic card Active has two male faston outlets 4 7 mm to allow the connection s...

Page 8: ...ke opening horizontal and the delivery opening vertical The pump must be installed exclusively in horizontal position Fig 3 To avoid transmitting vibrations to the system after delivery it is recommen...

Page 9: ...ct operating voltage and frequency are indicated on the pump data plate Never make any connection on the terminal card if the electric power supply has not been deactivated for at least 5 minutes 5 3...

Page 10: ...lectronic components of the pump if the power has not been turned off for at least 5 minutes If there is the risk of damage caused by frost drain the pump through the drainage cap Fig 12 The pump must...

Page 11: ...the voltage for a few seconds The existing pipe has a leak or is faulty Repair the pipe The pump does not stop The check valve is blocked or missing Clean the valve dismantling the system Dry running...

Page 12: ...50 M Jet 102 M Jetinox 102 M Jetcom 102 M Euro 30 50 M Euroinox 30 50 M Eurocom 40 50 M Jet 112 M Jetinox 112 M Euro 40 50 M Euroinox 40 50 M Jet 132 M Jetinox 132 M Jetcom 132 M Euro 50 50 M Euroinox...

Page 13: ...y specialised qualified personnel Reduce the system pressure it is recommended to close the valve of the system located for this purpose on delivery near the pump Disconnect the electric connectors of...

Page 14: ...n n montaj ACTIVE SYSTEM Montajul Kit ului Active System ACTIVE SYSTEM A J yZK Fig 15 Abb 15 Afb 15 15 Res 15 15 15 Z e 1 2 I Avvitare fino alla battuta F Visser fond GB Screw fully down D Bis zum An...

Page 15: ...EXION NORMALE GB NORMAL CONNECTION D NORMALER ANSCHLUSS NL NORMALE VERBINDING E CONEXI N NORMAL S NORMAL ANSLUTNING GR T NORMAL BA LANTI RU RM CONEXIUNE NORMAL n XBk Be G I CONNESSIONE ACTIVE F CONNEX...

Page 16: ...agram ladingverlies Diagrama p rdidas de carga Diagram ver tryckf rluster Y k kayb diyagram Diagrama pierderi de nc rc tur R A AXwt i iUK aZ Fig 17 Abb 17 Afb 17 17 Res 17 17 17 Z e ACTIVE Hydraulic L...

Page 17: ...E JC 132 48 3 48 3 ACTIVE E 25 30 25 306 34 5 35 9 ACTIVE E 30 30 30 306 46 48 2 ACTIVE E 40 30 40 306 57 58 8 ACTIVE E 30 50 30 506 42 5 38 8 ACTIVE E 40 50 40 506 57 5 54 ACTIVE E 50 50 50 506 72 66...

Page 18: ...113...

Page 19: ...114...

Page 20: ...05 06 cod 0013 600 17...

Reviews: