background image

                                                                   

ENGLISH                                                

 

22 

 

4.4  Stopping the pump 

The pump has a built-in electronic protection function 
which allows it to stop in the event of: 

− 

dry running, 

− 

overheating, 

− 

motor overload, 

− 

blockage of the pump / motor. 

 

After stopping in this way, the pump restarts 
automatically, making 3 attempts of 3 minutes each, 
with pauses of 10 seconds. 
The starting attempts will be repeated, in the event of 
a negative result: 

− 

after 1 hour :      1 attempt of 3 minutes, 

− 

after 4 hours :    1 attempt of 3 minutes, 

− 

every 15 hours : 1 attempt of 3 minutes. 

 

To perform manual resetting of the pump you must 
supply power to it again, disconnecting the voltage for 
a few seconds. 

 

5.  INSTALLATION AND CONNECTION 

5.1  Pump installation 

− 

The electropump must be installed in a well 
ventilated place, protected from inclement weather 
and with an environment temperature no higher 
than 40°C. 

− 

A solid anchoring of the pump to its support base 
helps absorb any vibrations created by pump
operation. 

− 

Always fit the pump on a base with the intake 
opening horizontal and the delivery opening 
vertical. 

− 

The pump must be installed exclusively in 
horizontal position (Fig.3): 

 

− 

To avoid transmitting vibrations to the system, after 
delivery it is recommended to use the flexible pipe 
that is supplied inside the packing. (Fig.4).

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 

− 

Do not allow the metal pipes to weigh down on the 
pump openings, transmitting excessive strain, so as 
not to create deformations or breakages. Anchor the 
pipes separately if possible. 

− 

The suction pipe must be as short as possible. For 
suction depths of more than 4 metres or with long 
horizontal stretches, it is recommended to use a 
suction pipe with a diameter larger than that of the 
suction opening of the electropump. 

− 

To avoid the formation of air pockets in the suction 
pipe, ensure a slight positive tilt of the same  towards 
the electropump. 

− 

If it is not possible to use the flexible pipe to make 
the connection, use only Teflon tape.  (Fig.5). 

 
 
 
 
 
 
 
 
 

− 

For any maintenance jobs it is recommended: 

• 

to fit an interception valve along the pipe, close 
to the pump (Fig.6), 

• 

to use a straight length of pipe, after delivery, for 
lifting the cover of the Active system, in the event 
of inspection (Fig.6). 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 3 

 

Fig. 6 

Fig. 4 

Fig. 5 

Summary of Contents for ACTIVE J 62

Page 1: ...CTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONSANWEISUNG UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERH LLS...

Page 2: ...N VERPANEL KONTROL PANELI PANOU DE CONTROL XB w A R TAPPO DI CARICO BOUCHON DE REMPLISSAGE FILLING CAP F LLSCHRAUBE VULDOP TAP N DE CARGA P FYLLNINGSPLUGG DOLDURMA TIPASI CAPAC DE NC RCARE IlK A Bio T...

Page 3: ...0 6 ACTIVE E 30 30 6 ACTIVE EI 30 30 6 ACTIVE EC 30 30 6 ACTIVE E 40 30 6 ACTIVE EI 40 30 6 ACTIVE E 30 50 6 ACTIVE EI 30 50 6 ACTIVE EC 30 50 6 ACTIVE E 40 50 6 ACTIVE EI 40 50 6 ACTIVE EC 40 50 6 AC...

Page 4: ...ingen DECLARACI N DE CONFORMIDAD La empresa DAB PUMPS s p a Via Marco Polo 14 Mestrino PD ITALY bajo su propia y exclusiva responsabilidad declara que los productos Active Active System rese ados ante...

Page 5: ...against dry running 1 1 Applications Active is used particularly for increasing pressure in storage tanks and for supplying water from wells in houses in holiday homes in farms in greenhouses and gar...

Page 6: ...or pumping water containing air hydraulic technopolymer suitable for pumping water containing air silent running silent running and stainless suitable for pumping water containing air hydraulic techno...

Page 7: ...cess temperature of hydraulic parts There is the possibility of remote signalling of the alarm signal in fact on the electronic card Active has two male faston outlets 4 7 mm to allow the connection s...

Page 8: ...ke opening horizontal and the delivery opening vertical The pump must be installed exclusively in horizontal position Fig 3 To avoid transmitting vibrations to the system after delivery it is recommen...

Page 9: ...ct operating voltage and frequency are indicated on the pump data plate Never make any connection on the terminal card if the electric power supply has not been deactivated for at least 5 minutes 5 3...

Page 10: ...lectronic components of the pump if the power has not been turned off for at least 5 minutes If there is the risk of damage caused by frost drain the pump through the drainage cap Fig 12 The pump must...

Page 11: ...the voltage for a few seconds The existing pipe has a leak or is faulty Repair the pipe The pump does not stop The check valve is blocked or missing Clean the valve dismantling the system Dry running...

Page 12: ...50 M Jet 102 M Jetinox 102 M Jetcom 102 M Euro 30 50 M Euroinox 30 50 M Eurocom 40 50 M Jet 112 M Jetinox 112 M Euro 40 50 M Euroinox 40 50 M Jet 132 M Jetinox 132 M Jetcom 132 M Euro 50 50 M Euroinox...

Page 13: ...y specialised qualified personnel Reduce the system pressure it is recommended to close the valve of the system located for this purpose on delivery near the pump Disconnect the electric connectors of...

Page 14: ...n n montaj ACTIVE SYSTEM Montajul Kit ului Active System ACTIVE SYSTEM A J yZK Fig 15 Abb 15 Afb 15 15 Res 15 15 15 Z e 1 2 I Avvitare fino alla battuta F Visser fond GB Screw fully down D Bis zum An...

Page 15: ...EXION NORMALE GB NORMAL CONNECTION D NORMALER ANSCHLUSS NL NORMALE VERBINDING E CONEXI N NORMAL S NORMAL ANSLUTNING GR T NORMAL BA LANTI RU RM CONEXIUNE NORMAL n XBk Be G I CONNESSIONE ACTIVE F CONNEX...

Page 16: ...agram ladingverlies Diagrama p rdidas de carga Diagram ver tryckf rluster Y k kayb diyagram Diagrama pierderi de nc rc tur R A AXwt i iUK aZ Fig 17 Abb 17 Afb 17 17 Res 17 17 17 Z e ACTIVE Hydraulic L...

Page 17: ...E JC 132 48 3 48 3 ACTIVE E 25 30 25 306 34 5 35 9 ACTIVE E 30 30 30 306 46 48 2 ACTIVE E 40 30 40 306 57 58 8 ACTIVE E 30 50 30 506 42 5 38 8 ACTIVE E 40 50 40 506 57 5 54 ACTIVE E 50 50 50 506 72 66...

Page 18: ...113...

Page 19: ...114...

Page 20: ...05 06 cod 0013 600 17...

Reviews: