Model 

P1=540 W 

P1=830 W 

P1=1050 W 

Electrical data 

P1 Rated absorbed power [W] 

540 

830 

1050 

P2 [W] 

400 

570 

710 

USA P2 [HP] Fractional (decimal) 

1/3 (0.3) 

1/2 (0.5) 

3/4 (0.75) 

Mains voltage [V] 

~ 115-120V AC 

Mains frequency [Hz] 

60 

Current [A] 

5.5 

7.9 

9.3 

Capacitor [µF] 

30 

35 

Capacitor [Vc] 

250 

Hydraulic data 

Max. flow rate [gpm] 

26.4 

Max. head [ft] 

78.7 

114.8 

150.9 

Max. head [psi] 

34.8 

50.8 

66.7 

Max. immersion depth [ft] 

39.4 

Min. submersion height [in] 

4.7 

N. of impellers 

Range of use 

Length of power cable [ft] 

49.2 

Type of cable 

SJTOW 16AWG 

Grade of motor protection 

IP 68 / NEMA 6P 

Insulation class 

Liquid temperature range [F] 

according to EN 60335-2-41 for domestic use

 

+32 F / +95 F 

Max. particle dimension [in] 

0.04 

Max. ambient temperature [F] 

104 

Weight 

DNM NPT 

1'' F 

Table 2 

 

AdBlue versions may have specific technical data: check the technical label on the product. 

 

The pump which does not stand on a base cannot support the weight of the pipes, which must be 
supported in some other way.

 

 

4.  MANAGEMENT 

4.1 Storage 

All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust. 
They are supplied in their original pack in which they must remain until the time of installation. 
 

4.2  Transport 

Avoid subjecting the products to needless impacts and collisions. 

 

4.3 Weight 

and 

dimensions 

The adhesive plate on the packaging indicates the total weight of the pump and its dimensions. 

 

5.  WARNINGS 

 

The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use 
the handle and cord provided. 

 

Before installation, dredge any sand and other solid particles from the cistern. 

 

The motor’s power cord must be secured to the delivery pipe with plastic clamps every 2 or 3 m (6 or 
10 ft). 

 

Use the check valve provided. 

 

 

The pump must never be allowed to run when dry.

 

 

The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the 
case of pure water, if the pump were to have any leaks.

 

 

6.  INSTALLATION 

The electrical system must be compliant with local norms. 

Screw first the non-return valve and then the nipple using the connector ideal for ¾’’ and 1’’ pipes provided in the 
packaging. If a pipe with greater diameter is to be used, change the connector. Use a pipe tightening clamp to secure the 
pipe to the fitting Fig.1 

  It is advisable to use pipes having a minimum internal diameter of ¾’’, to avoid the decrease of pump performance. 

Summary of Contents for DIVER 6 1050 W

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE GB INSTRUCTIONS POUR L INSTALLATION ET LA MAINTENANCE FR INSTRUCCIONES DE INSTALACI N Y MANTENIMIENTO ES INSTRU ES PARA A INSTALA AO PT...

Page 2: ...ENGLISH Pag 1 FRAN AIS Page 5 ESPA OL P g 9 PORTUGU S pag 13...

Page 3: ...A NA Automatic Not Automatic Automatique Pas Automatique Autom tico No autom tico Autom tico N o autom tico...

Page 4: ...1 2 3 4 5...

Page 5: ...e cause of the overheating See Troubleshooting 1 APPLICATIONS Powerful multistage submersible pump ideal for rainwater systems operating sprinklers pumping water from cisterns tanks ponds and other ap...

Page 6: ...They are supplied in their original pack in which they must remain until the time of installation 4 2 Transport Avoid subjecting the products to needless impacts and collisions 4 3 Weight and dimensio...

Page 7: ...ls the pump starting and stopping ON OFF depending on its position The models with a float switch are started automatically when the water level rises and will switch off when the required minimum lev...

Page 8: ...y blocked B The impeller or delivery pipe are partially blocked or encrusted A Remove any obstruction B Remove any obstruction The pump does not stop A The pump is not disabled by the float A Make sur...

Page 9: ...le pour une utilisation dans les syst mes d eau de pluie arroseurs pomper l eau des citernes r servoirs et pour les applications n cessitant une haute pression Compos e de mat riaux anti corrosion ave...

Page 10: ...elle ci doit tre suspendue imp rativement au moyen de la corde fournie ou d un c ble inox de 4 mm non fourni 4 GESTION 4 1 Stockage Toutes les pompes doivent tre stock es dans un endroit couvert sec e...

Page 11: ...n pour l utilisation de celle ci Respecter les indications pr sentes sur la plaque technique et dans le tableau 2 de ce manuel 8 D MARRAGE Le flotteur commande automatiquement le d marrage et l arr t...

Page 12: ...ou incrust s A liminer les ventuelles obstructions B liminer les ventuelles obstructions La pompe ne s arr te pas A La pompe n est pas d sactiv e par le flotteur A V rifier que le flotteur bouge libr...

Page 13: ...as de reutilizaci n del agua de lluvia aspersores bombeo de agua de cisternas tanques estanques y otras aplicaciones que requieran alta presi n Las caracter sticas incluyen materiales anti corrosi n y...

Page 14: ...base no puede sostener el peso de las tuber as que habr que sostener de otra manera 4 GESTI N 4 1 Almacenaje Hay que almacenar todas las bombas en un lugar cubierto seco y con humedad del aire posibl...

Page 15: ...est dotada la bomba limita la profundidad m xima de inmersi n de la misma Atenerse a las indicaciones dadas en la placa de datos t cnicos y en la tabla 2 de este manual 8 PUESTA EN MARCHA El flotador...

Page 16: ...de impulsi n no est n parcialmente obstruidos o con incrustaciones A Elimine posibles obstrucciones B Elimine posibles obstrucciones La bomba no se detiene A La bomba no es desactivada por el flotado...

Page 17: ...riga o bombagem de gua de cisternas tanques lagos e para outras aplica es que necessitam de alta press o As principais caracter sticas incluem materiais anticorrosivos e resistentes poeira prote o de...

Page 18: ...mba que n o est apoiada sobre uma base n o pode sustentar o peso de tubagens Este peso deve ser apoiado em outra posi o 4 GEST O 4 1 Armazenagem Todas as bombas devem ser armazenadas em lugar coberto...

Page 19: ...cabo de alimenta o presente na bomba limita a profundidade m xima de imers o para a utiliza o da mesma Seguir as instru es da placa de caracter sticas t cnicas e o quadro 2 deste manual 8 ARRANQUE A b...

Page 20: ...ialmente obstru da B Verifique se o rotor ou o tubo de compress o n o est o parcialmente obstru dos ou com incrusta es A Retire eventuais obstru es B Retire eventuais obstru es A bomba n o p ra A A bo...

Page 21: ...01 19 cod 60186591...

Reviews: