DAB PUMPS DIVER 6 1050 W Instruction For Installation And Maintenance Download Page 5

ENGLISH 

 

 

INDEX 
 

1.  APPLICATIONS ........................................................................................................................................... 1

 

2.  PUMPABLE LIQUIDS .................................................................................................................................. 1

 

3.  TECHNICAL DATA AND LIMITATIONS OF USE ...................................................................................... 1

 

4.  MANAGEMENT ............................................................................................................................................ 2

 

4.1

 

Storage ................................................................................................................................................ 2

 

4.2

 

Transport ............................................................................................................................................... 2

 

4.3

 

Weight and dimensions ....................................................................................................................... 2

 

5.  WARNINGS .................................................................................................................................................. 2

 

6.  INSTALLATION ........................................................................................................................................... 2

 

7.  ELECTRICAL CONNECTION ...................................................................................................................... 3

 

8.  START-UP .................................................................................................................................................... 3

 

9.  PRECAUTIONS ............................................................................................................................................ 3

 

10.  MAINTENANCE AND CLEANING ............................................................................................................ 3

 

10.1 Cleaning the suction filter ..................................................................................................................... 4

 

10.2 Cleaning the impeller ............................................................................................................................ 4

 

11.  TROUBLESHOOTING ............................................................................................................................... 4

 

12.  GUARANTEE ............................................................................................................................................. 4

 

 
WARNINGS 

 

Read all this documentation carefully before installation:

 

 

Take out the plug before any intervention. Absolutely avoid dry operation: the pump must be 
activated exclusively when it is immersed in water. If the water is finished, the pump must be 
deactivated immediately, taking the plug out of the socket. 

 

 

The pump is equipped with a thermal overload safety device. In the event of any overheating of the 
motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 
minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is 
essential to identify and deal with the cause of the overheating. See Troubleshooting.

 

 

1.  APPLICATIONS 

Powerful multistage submersible pump ideal for rainwater systems, operating sprinklers, pumping water from cisterns, 
tanks, ponds and other applications that require high pressure. Anti-corrosive and dust proof materials, overload 
protection, wear resistant shaft, anti-debris stainless steel strainer, excellent cooling of the motor allowing the pump to 
run even if partially submerged, automatic start/stop function with floating switch. Supplied with non-return valve and     
4-step fitting.

 

 

 

These pumps cannot be used in swimming pools, ponds or basins where people are present, or for 
pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the 
accident prevention regulations in force. They should be cleaned before putting them away. See the 
chapter “Maintenance and Cleaning”.

 

 

2.  PUMPABLE LIQUIDS 

Fresh water

 

 

 

Rainwater

 

 

 

Clear waste water 

 

o

   

Dirty water 

o

   

Fountain water 

 

 

River or lake water 

 

 

Max. particle dimension [in] 

Ø 0.04 

       Suitable 

o

 Not 

suitable 

 

 3.  TECHNICAL DATA AND LIMITATIONS OF USE 

 

Supply voltage

: 115-120V, 

see electrical data plate

 

 

Delayed line fuses (

115-120V 

version):

 indicative values (Ampere) 

 

Storage temperature

14 F – 104 F

 

 
 
 

Table1 

Summary of Contents for DIVER 6 1050 W

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE GB INSTRUCTIONS POUR L INSTALLATION ET LA MAINTENANCE FR INSTRUCCIONES DE INSTALACI N Y MANTENIMIENTO ES INSTRU ES PARA A INSTALA AO PT...

Page 2: ...ENGLISH Pag 1 FRAN AIS Page 5 ESPA OL P g 9 PORTUGU S pag 13...

Page 3: ...A NA Automatic Not Automatic Automatique Pas Automatique Autom tico No autom tico Autom tico N o autom tico...

Page 4: ...1 2 3 4 5...

Page 5: ...e cause of the overheating See Troubleshooting 1 APPLICATIONS Powerful multistage submersible pump ideal for rainwater systems operating sprinklers pumping water from cisterns tanks ponds and other ap...

Page 6: ...They are supplied in their original pack in which they must remain until the time of installation 4 2 Transport Avoid subjecting the products to needless impacts and collisions 4 3 Weight and dimensio...

Page 7: ...ls the pump starting and stopping ON OFF depending on its position The models with a float switch are started automatically when the water level rises and will switch off when the required minimum lev...

Page 8: ...y blocked B The impeller or delivery pipe are partially blocked or encrusted A Remove any obstruction B Remove any obstruction The pump does not stop A The pump is not disabled by the float A Make sur...

Page 9: ...le pour une utilisation dans les syst mes d eau de pluie arroseurs pomper l eau des citernes r servoirs et pour les applications n cessitant une haute pression Compos e de mat riaux anti corrosion ave...

Page 10: ...elle ci doit tre suspendue imp rativement au moyen de la corde fournie ou d un c ble inox de 4 mm non fourni 4 GESTION 4 1 Stockage Toutes les pompes doivent tre stock es dans un endroit couvert sec e...

Page 11: ...n pour l utilisation de celle ci Respecter les indications pr sentes sur la plaque technique et dans le tableau 2 de ce manuel 8 D MARRAGE Le flotteur commande automatiquement le d marrage et l arr t...

Page 12: ...ou incrust s A liminer les ventuelles obstructions B liminer les ventuelles obstructions La pompe ne s arr te pas A La pompe n est pas d sactiv e par le flotteur A V rifier que le flotteur bouge libr...

Page 13: ...as de reutilizaci n del agua de lluvia aspersores bombeo de agua de cisternas tanques estanques y otras aplicaciones que requieran alta presi n Las caracter sticas incluyen materiales anti corrosi n y...

Page 14: ...base no puede sostener el peso de las tuber as que habr que sostener de otra manera 4 GESTI N 4 1 Almacenaje Hay que almacenar todas las bombas en un lugar cubierto seco y con humedad del aire posibl...

Page 15: ...est dotada la bomba limita la profundidad m xima de inmersi n de la misma Atenerse a las indicaciones dadas en la placa de datos t cnicos y en la tabla 2 de este manual 8 PUESTA EN MARCHA El flotador...

Page 16: ...de impulsi n no est n parcialmente obstruidos o con incrustaciones A Elimine posibles obstrucciones B Elimine posibles obstrucciones La bomba no se detiene A La bomba no es desactivada por el flotado...

Page 17: ...riga o bombagem de gua de cisternas tanques lagos e para outras aplica es que necessitam de alta press o As principais caracter sticas incluem materiais anticorrosivos e resistentes poeira prote o de...

Page 18: ...mba que n o est apoiada sobre uma base n o pode sustentar o peso de tubagens Este peso deve ser apoiado em outra posi o 4 GEST O 4 1 Armazenagem Todas as bombas devem ser armazenadas em lugar coberto...

Page 19: ...cabo de alimenta o presente na bomba limita a profundidade m xima de imers o para a utiliza o da mesma Seguir as instru es da placa de caracter sticas t cnicas e o quadro 2 deste manual 8 ARRANQUE A b...

Page 20: ...ialmente obstru da B Verifique se o rotor ou o tubo de compress o n o est o parcialmente obstru dos ou com incrusta es A Retire eventuais obstru es B Retire eventuais obstru es A bomba n o p ra A A bo...

Page 21: ...01 19 cod 60186591...

Reviews: