9
Advantage
®
Electrol
®
Installation for 220V Screens (continued)
220V Wiring Diagram with European Style Wall Switch
Use 3-conductor 20–24 gauge wire for wall switch connections.
IMPORTANT NOTE:
The European style wall switch is for
operation only and CANNOT be used to make limit switch
adjustments. Therefore, it is advised to wire the limit adjustment
switch or provide a 3-conductor connection that is accessible.
Power Input 220VAC / 50Hz
Green / Yellow (Ground)
Blue
(Hot)
Brown
(Common)
Power
Wire
Data
Cable
RJ-45 Jack
Black (Down)
White (Common)
Red (Up)
Red
Black
White
Inputs
Output
Black (Down)
White (L / Common)
Red (Up)
Push Down on Tab to
Insert Wire
L