xStack
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch
84
deleted.
Countdown Time
Displays the current time remaining before this Analyzer server times out. When the server
times out, all sFlow samples and counter polls associated with this server will be deleted.
Address
Displays the IP address of the sFlow Analyzer Server. This IP address is where sFlow
datagrams will be sent for analysis.
Port
Displays the previously configured UDP port where sFlow datagrams will be sent for analysis.
Max Datagram Size
This field displays the maximum number of data bytes in a single sFlow datagram that will be
sent to this sFlow Analyzer Server.
Modify
Click the
Modify
button to display the
sFlow Counter Analyzer Edit
window, so that users
may edit the settings for this server.
Delete
Click the corresponding
button of the entry to be deleted.
To add a new sFlow Analyzer, click the
Add
button in the previous window that will display the following window to be
configured:
Figure 2 - 92 sFlow Analyzer – Add window
The following fields can be set or modified:
Parameter Description
Analyzer Server (1-
4)
Enter an integer from
1
to
4
to denote the sFlow Analyzer to be added. Up to four entries can
be added.
Owner
Users may enter an alphanumeric string of up to 16 characters to define the owner of this
entry. Users are encouraged to give this field a name that will help them identify this entry.
When an entry is made in this field, the following Timeout field is automatically set to
400
seconds, unless the user alters the Timeout field.
Timeout (1-2000000
sec)
This field is used to specify the timeout for the Analyzer server. When the server times out, all
sFlow samples and counter polls associated with this server will be deleted. The user may set
a time between
1
and
2000000
seconds with a default setting of
400
seconds.
Infinite
can be
selected to ensure that it never times out.
Collector Address
The IP address of the sFlow Analyzer Server. If this field is not specified, the entry will become
0.0.0.0 and therefore the entry will be inactive. Users must set this field.
Collector Port (1-
The destination UDP port where sFlow datagrams will be sent. The default setting for this field