xStack
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch
40
configuration uploads, select the Image ID of the configuration. Choosing
Active
will upload
the Boot Up Image ID configuration to the TFTP server. And user can upload configuration of
Image 1 or 2 by choosing Image ID.
Server IPv4 Address
Enter the IPv4 address of the server from which to download firmware and configuration or
upload configuration and log.
Server IPv6 Address
Enter the IPv6 address of the server from which to download firmware and configuration or
upload configuration and log.
The Interface field is used for addresses on the link-local network. It is recommended that the
user enter the specific interface for a link-local IPv6 address. For Global IPv6 addresses, this
field may be omitted.
File Name
Enter the path and filename of the firmware or configuration file to upload or download. The
file to be uploaded or downloaded must have the same path with the TFTP server.
Multiple Image Services
The
Multiple Image Services
folder allows users of the Switch to configure and view information regarding firmware located on
the Switch. The Switch allows two firmware images to be stored in its memory and either can be configured to be the boot up
firmware for the Switch. For information regarding firmware images located on the Switch, click the
Firmware Information
link.
The default setting will have the boot up firmware stored as Image 1, but the user may set either stored firmware to be the boot up
firmware by using the
Config Firmware Image
window.
Firmware Information
The following window allows the user to
view information about current firmware
images stored on the Switch.
To view this window, click
Administration
> Multiple Image Services > Firmware
Information
, as shown on the right:
Figure 2 - 34 Firmware Information window
This window holds the following information:
Parameter Description
ID
States the image ID number of the firmware in the Switch’s memory. The Switch can store 2
firmware images for use. Image ID 1 will be the default boot up firmware for the Switch unless
otherwise configured by the user.
Version
States the firmware version.
Size
States the size of the corresponding firmware, in bytes.
Update Time
States the specific time the firmware version was downloaded to the Switch.
From
States the IP address of the origin of the firmware. There are five ways firmware may be
downloaded to the Switch. Boot Up files are denoted by an asterisk (*) next to the file.
R – If the IP address has this letter attached to it, it denotes a firmware upgrade through the