D-Link DGS-3324SRi Intelligent Stackable Gigabit Ethernet Switch
149
Figure 6- 13. Rx Size Analysis window (table)
The following fields can be set:
Parameter Description
Time Interval [
1s
]
Select the desired setting between
1s
and
60s
, where “s” stands for
seconds. The default value is one second.
Record Number
[
200
]
Select number of times the Switch will be polled between
20
and
200
. The
default value is
20.
64
The total number of packets (including bad packets) received that were 64
octets in length (excluding framing bits but including FCS octets).
65-127
The total number of packets (including bad packets) received that were
between 65 and 127 octets in length inclusive (excluding framing bits but
including FCS octets).
128-255
The total number of packets (including bad packets) received that were
between 128 and 255 octets in length inclusive (excluding framing bits but
including FCS octets).
256-511
The total number of packets (including bad packets) received that were
between 256 and 511 octets in length inclusive (excluding framing bits but
including FCS octets).
512-1023
The total number of packets (including bad packets) received that were
between 512 and 1023 octets in length inclusive (excluding framing bits but
including FCS octets).
1024-1518
The total number of packets (including bad packets) received that were
between 1024 and 1518 octets in length inclusive (excluding framing bits
but including FCS octets).
Summary of Contents for xStack DGS-3324SRi