xStack DES-6500 Modular Layer 3 Chassis Ethernet Switch User Manual
Unit
Choose the unit of the switch in the chassis to be configured.
Choose Member Ports
Choose the members of a trunked group. 2 to 8 ports can be assigned to an individual
group.
Active Port
Shows the port that is currently forwarding packets.
Flooding Port
A trunking group must designate one port to allow transmission of broadcasts and
unknown unicasts.
After setting the previous parameters, click
Apply
to allow changes to be implemented. Successfully created trunk groups will be
show in the
Current Link Aggregation Group Entries
.
LACP Port Settings
The
LACP Port Settings
window is used in conjunction with the
Link Aggregation
window to create port trunking groups on
the Switch. Using the following window, the user may set which ports will be active and passive in processing and sending LACP
control frames.
Figure 6- 10. LACP Port Setting and LACP Port Information window
The user may set the following parameters:
Parameter Description
Unit
Choose the switch in the chassis to be configured by using the pull-down menu.
From/To
A consecutive group of ports may be configured starting with the selected port.
Mode
Active
- Active LACP ports are capable of processing and sending LACP control frames. This
allows LACP compliant devices to negotiate the aggregated link so the group may be changed
dynamically as needs require. In order to utilize the ability to change an aggregated port group, that
is, to add or subtract ports from the group, at least one of the participating devices must designate
LACP ports as active. Both devices must support LACP.
Passive
- LACP ports that are designated as passive cannot initially send LACP control frames. In
order to allow the linked port group to negotiate adjustments and make changes dynamically, one
end of the connection must have "active" LACP ports (see above).
After setting the previous parameters, click
Apply
to allow your changes to be implemented. The
LACP Port Table
shows which
ports are active and/or passive.