Using IP surveillance Software (continued)
Alert Message
If you have checked the box “Enable Motion Detect” or “Enable Digital Input” on
the Camera Configurations > Alert Settings screen, the alert message will show
in the window shown above. Once the alert, caused by motion detection or a
digital input level change is triggered, the alert message will be shown in this
window. If there are more events than this window can display, a scroll bar will
appear.
The message format is described as follows:
“time”=>”alert type” #”channel number”(“win1”,”win2",”win3")
For example, the message “PM 02:41:00=>MO #1(0,1,1)” means that this is a
motion detection alert occurring at 02:41:00 PM in Motion Window 2 and Motion
Window 3, for camera #1. If the message “PM 02:41:56=>DI #1” is listed, that
means there is an alert triggered by the DI, for camera #1, at 02:41:56 PM .
Monitor Program (continued)