LED
Color
Status
Description
Locator
Blue
On (Solid)
User logged in
-
Off
Locator function is disabled
Power
Green
On (Solid)
Power on
On (Blinking)
Performing system self-test
Amber
On (Solid)
PSU failed or Voltage/Current/Temperature too high
-
Off
Power off
Status
Green
On (Solid)
POST passed and normal operation
On (Blinking)
POST in progress
Amber
On (Blinking)
POST/PSU/Fan failed or Temperature too high
-
Off
Power off
Fan
Green
On (Solid)
Fan operation normal
Amber
On (Blinking)
Fan error
-
Off
Power off
Link/Act
(Out-Of-Band port)
Green
On (Solid)
Active connection through the port
On (Blinking)
Data transmitted and received through the port
-
Off
Inactive connection, no link present, or port disabled
Link/Act
(10GE SFP+ ports)
Green
On (Solid)
Active connection at 10 Gbps through the port
On (Blinking)
Data transmitted and received through the port
Amber
On (Solid)
Active connection at 1 Gbps through the port
On (Blinking)
Data transmitted and received through the port
-
Off
Inactive connection, no link present, or port disabled
Link/Act
(100GE QSFP28 ports)
White
(LED 1)
On (Solid)
Active connection at 100 Gbps through the port
On (Blinking)
Data transmitted and received through the port
Blue
(LED 4)
On (Solid)
Active connection at 40 Gbps through the port
On (Blinking)
Data transmitted and received through the port
-
Off
Inactive connection, no link present, or port disabled
Stacking
(Master)
(100GE QSFP28 ports)
White
(LED 1)
Amber
(LED 2)
On (Solid)
Active connection at 100 Gbps through the port and
the Switch is the
Master
switch in the stack
On (Blinking)
Data transmitted and received through the port
-
Off
No link present
Stacking
(Slave)
(100GE QSFP28 ports)
Amber
(LED 3)
Blue
(LED 4)
On (Solid)
Active connection at 100 Gbps through the port and
the Switch is a
Slave
switch in the stack
On (Blinking)
Data transmitted and received through the port
-
Off
No link present
Rear Panel
The rear panel features components like LED indicators, PSU (Power Supply Unit) modules, fan modules,
and an electrical grounding point. These components are described in detail below.
CAUTION
: When two PSU modules are installed, they must be the
same type
(two AC
or two DC) and also use the same airflow direction (back-to-front or front-to-back).
4
Summary of Contents for DXS-3610-54S
Page 20: ...DXS 3610 54S DXS 3610 54S 2 AC DXS PWR700AC 5 DXS FAN200 AC RJ45 RS 232 USB 4 2 20...
Page 24: ...5 DXS 3610 54S 6 24...
Page 25: ...19 DXS 3610 54S 19 7 8 9 25...
Page 26: ...10 DGS 3610 54S QSFP28 SFP QSFP QSFP28 100GE QSFP28 11 QSFP QSFP28 QSFP28 26...
Page 27: ...SFP SFP 10GE SFP 12 SFP SFP SFP AC DXS 3610 54S AC 27...
Page 28: ...13 AC 14 AC PSU 2 AC AC 100 240 50 60 DC DXS 3610 54S DC 28...
Page 29: ...15 DC 16 DC PSU 2 DC DC 48 5 2 A 17 DC DC 29...
Page 30: ...DGS 3610 54S DXS FAN200 18 19 30...
Page 31: ...DXS 3610 54S 12 IP Telnet Web RJ45 SFP QSFP28 SNMP 20 21 31...
Page 38: ...38...