DXS-3326GSR Gigabit Layer 3 Switch
Figure 10- 14. Rx Size Analysis window (table)
The following fields can be set or viewed:
Parameter Description
Unit
Select the unit to display statistics for.
Port
Select the port to display statistics for.
Clear
Clicking this button clears all statistics counters on this window.
Time Interval
Select the desired setting between
1s
and
60s
, where "s" stands for seconds. The
default value is one second.
Record Number
Select number of times the Switch will be polled between
20
and
200
. The default
value is
200
.
64
The total number of packets (including bad packets) received that were
64
octets in
length (excluding framing bits but including FCS octets).
65-127
The total number of packets (including bad packets) received that were between
65
and
127
octets in length inclusive (excluding framing bits but including FCS octets).
128-255
The total number of packets (including bad packets) received that were between
128
and
255
octets in length inclusive (excluding framing bits but including FCS
octets).
256-511
The total number of packets (including bad packets) received that were between
256
and
511
octets in length inclusive (excluding framing bits but including FCS
octets).
512-1023
The total number of packets (including bad packets) received that were between
512
and
1023
octets in length inclusive (excluding framing bits but including FCS
octets).