DXS-1210 Series Smart Managed Switch CLI Reference Guide
95
Parameters
interface INTERFACE-ID
(Optional) Specifies the interface’s ID. The acceptable interface will be
a physical port.
,
(Optional) Specifies a series of interfaces, or separate a range of
interfaces from a previous range. No space before and after the
comma.
-
(Optional) Specifies a range of interfaces. No space before and after
the hyphen.
Default
None.
Command Mode
EXEC Mode.
Command Default Level
Level: 1.
Usage Guideline
This command is used to display the test results for the cable diagnostics.
Example
This example shows how to display the test results for the cable diagnostics.
Switch# show cable-diagnostics
Port Type Link Status Test Result Cable Length (M)
------ ---------- ------------- ------------------------------ ----------------
-
eth1/0/1 1000BASE-T Link Up OK 65
eth1/0/2 1000BASE-T Link Up OK -
eth1/0/3 1000BASE-T Link Down Shutdown 25
eth1/0/4 1000BASE-T Link Down Shutdown -
eth1/0/5 1000BASE-T Link Down Unknown -
eth1/0/6 1000BASE-T Link Down Pair 1 Crosstalk at 30M -
Pair 2 Crosstalk at 30M
Pair 3 OK at 110M
Pair 4 OK at 110M
eth1/0/7 1000BASE-T Link Down NO Cable -
eth1/0/8 1000BASE-T Link Down Pair 1 Open at 16M -
Pair 2 Open at 16M
Pair 3 OK at 50M
Pair 4 OK at 50M
Switch#
10-3
clear cable-diagnostics
This command is used to clear the test results for the cable diagnostics.
clear cable-diagnostics {all | interface INTERFACE-ID [,|-]}
Parameters