DXS-1210 Series Smart Managed Switch CLI Reference Guide
170
23.
Jumbo Frame Commands
23-1
max-rcv-frame-size
This command is used to configure the maximum Ethernet frame size allowed. Use the no form of this
command to revert to the default setting.
max-rcv-frame-size BYTES
no max-rcv-frame-size
Parameters
BYTES
Specifies the maximum Ethernet frame size allowed.
Default
By default, this value is 1536 bytes.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is available for physical ports configuration. Oversize frames will be dropped and
checks are carried out on ingress ports. Use this command to transfer large frames or jumbo frames
through the switch system to optimize server-to-server performance.
Example
This example shows how to configure the maximum received Ethernet frame size to be 6000 bytes on
port 4/0/1.
Switch# configure terminal
Switch(config)#interface eth4/0/1
Switch(config-if)# max-rcv-frame-size 6000
Switch(config-if)#