DXS-1210 Series Smart Managed Switch CLI Reference Guide
17
show version
Parameters
None.
Default
None.
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
This command displays version information about the Switch.
Example
This example shows how to displays version information about the Switch.
Switch#show version
System MAC Address: 3C-1E-04-A1-CC-00
Module Name Versions
------------------ ---------------------
DXS-1210-12SC H/W:A2
Bootloader:1.00.006
Runtime:1.15.005
Switch#
2-11
snmp-server enable traps environment
This command is used to enable the power, temperature and fan trap state.
snmp-server enable traps environment [fan] [temperature]
no snmp-server enable traps environment [fan] [temperature]
Parameters
fan
(Optional) Specifies to enable the fan trap state for warning fan event
(fan failed or fan recover).
temperature
(Optional) Specifies to enable the temperature trap state for warning
temperature event (temperatureexceeds the thresholds or
temperaturerecover).
Default
None.
Command Mode
Global Configuration Mode.