background image

D-Link Systems, Inc.

5

DWS-1008 Install Guide

Installation Overview

Caution:

  To  reduce  the  risk  of  equipment  damage,  make  sure  the  switch 

is  installed  so  that  the  mechanical  load  on  the  device  is  evenly  distributed. 

For example, make sure the switch is level in the equipment rack, is evenly 

fastened by screws on either side, and does not have a heavy object resting 

on one side of the switch.

Mounting Option 

Required Hardware and Tools  

Included

Front-mount 

 

Mounting brackets 

 

 

   Yes

 

 

 

Four rack-mount screws  

 

   No*

 

 

 

Screwdriver 

 

 

 

   No

 

 

 

Power cord 

 

 

 

   Yes

 

 

 

Serial console cable 

 

 

   Yes

Tabletop 

 

Four adhesive rubber feet  

 

   Yes

 

 

 

Power cord 

 

 

 

   Yes

 

 

 

Serial console cable 

 

 

   Yes

Equipment racks vary, and the screw and screwdriver type depend on the 

equipment rack.

You  can  mount  the  DWS-1008  switch  in  a  standard  48.26-cm  (19-inch) 

equipment  rack  or  on  a  tabletop.  Each  switch  is  shipped  with  two  brackets 

for rack mounting and four adhesive rubber feet for tabletop mounting. The 

mounting brackets support front mounting only.

Warning:

 Earth grounding is required for a DWS-1008 switch installed in a 

rack. If you are relying on the rack to provide ground, the rack itself must be 

grounded with a ground strap to the earth ground. Metal screws attaching the 

switch to the rack provide ground attachment to the rack.

In the U.S., overcurrent protection must be provided by the installation. Branch 

circuit  protection  in  accordance  with  National  Fire  Protection  Association 

(NFPA) 70, National Electrical Code (NEC) is required. Consideration must be 

given to the electrical ratings on the switch and branch circuit protection. Do 

not install equipment such that the branch circuit current and voltage protection 

is exceeded. Pay particular attention to the earthing connection for the supply 

connections. When using an extension cord or power strip, pay attention to the 

grounding type. 

Installation Overview (continued)

Summary of Contents for DWS-1008

Page 1: ......

Page 2: ...stall Guide Power Supply Serial Cable for Connection to Console Rack Mount Brackets 2 Screws 6 Rubber Feet 4 Manual and Reference Guide on CD Caution The DWS 1008 switch has been designed and tested to be installed in an operating ambient temperature of 0 C to 40 C 32 F to 104 F To reduce the risk of equipment damage install equipment with consideration to these ambient conditions System Requireme...

Page 3: ...tion to power source Link 1 8 Solid Link is operational Amber 10Mbps Green 100Mbps Blinking Traffic is active Amber 10Mbps Green 100Mbps MP 1 6 Solid green For a DWL 8220AP s active link with PoE enabled all the following are true Access point has booted Access point has received a valid configuration from the switch Management link with an access point is operational Alternating green Access point ...

Page 4: ...ons on the 10 100 ports require CAT5 cable based on the EIA TIA 586 standard The 10 100 Ethernet ports on the DWS 1008 switch provide automatic MDI MDX which automatically crosses over the send and receive signals if required The table below lists the pin signals for 10 100 Ethernet straight through wiring Pins 4 5 7 and 8 are used only when Power over Ethernet PoE is enabled on the port RD means ...

Page 5: ...tch is shipped with two brackets for rack mounting and four adhesive rubber feet for tabletop mounting The mounting brackets support front mounting only Warning Earth grounding is required for a DWS 1008 switch installed in a rack If you are relying on the rack to provide ground the rack itself must be grounded with a ground strap to the earth ground Metal screws attaching the switch to the rack p...

Page 6: ... is built in to the firmware on the DWS 1008 switch No additional software is required The switch supports two connection modes Administrative access mode which enables the network administrator to connect to the switch and configure the network Network access mode which enables network users to connect through the switch to access the network The D Link Mobility System consists of the following com...

Page 7: ...ent the switch from slipping do not release the switch until all the rack mount screws are tight Tabletop Installation 1 On a clean work surface with no debris carefully turn the switch upside down 2 Wipe the four placement locations for the rubber feet to clear away any oil or dust The location areas are marked by X s and attach the four rubber adhesive feet over the X s 3 Turn the switch right s...

Page 8: ... bps 8 bits 1 stop No parity Hardware flow control off or disabled 4 Open a connection on a serial port If the switch is already powered on press Enter three times to display a command prompt Refer to the Accessing the CLI for more information Troubleshooting a Serial Management Connection 1 Verify that the switch is powered on 2 Verify that the serial cable is fully inserted in the PC and switch s...

Page 9: ...ains plug for the mains 1 Insert a CAT5 cable with a standard RJ 45 connector The 10 100 Ethernet ports on the DWS 1008 switch provide automatic MDI MDX 2 If the cable is directly attached to a DWL 8220AP access point For a first time installation set the port type to activate the link If the port type is already set for an access point observe the appearance of the MP LED for the port 3 If the cab...

Page 10: ...re a new switch or to continue configuration of a partially configured switch CLI Command Line Interface You can configure a switch using the CLI by attaching a PC to the switch s Console port After you configure the switch for SSH or Telnet access you also can use these protocols to access the CLI Configuration ...

Page 11: ...next item and accept the default if applicable by pressing Enter Depending on your input the command also automatically generates the following key pairs and self signed certificates SSH key pair always generated Admin key pair and self signed certificate always generated EAP 802 1X key pair and self signed certificate generated if you type usernames and passwords for users of encrypted SSIDs WebAAA ...

Page 12: ...r password prompt 5 Type quickstart The command asks you a series of questions You can type for more help To quit press Ctrl C One of the questions the script asks is the country code For a list of valid country codes refer to the section Appendix Country of Operation Another question the script asks is Do you wish to configure wireless If you answer y the script goes on to ask you for SSID and use...

Page 13: ...ss2 for WebAAA Encrypted SSID name corporate Username alice and password alicepass for 802 1X authentication username bob and password bobpass for 802 1X authentication Directly connected DWL 8220AP access points on port 2 and 3 The IP addresses usernames and passwords in this document are examples Use values that are appropriate for your organization If you configure time and date parameters you w...

Page 14: ...e Contacting Technical Support Configuration continued 6 Optionally enable Telnet DWS 1008 aabbcc set ip telnet server enable 7 Verify the configuration changes DWS 1008 aabbcc show config 8 Save the configuration changes DWS 1008 aabbcc save config ...

Page 15: ...D Link Systems Inc 15 DWS 1008 Install Guide Notes Notes ...

Page 16: ...rs can contact D Link Technical Support through our website or by phone United States Telephone 877 453 5465 Monday through Friday 8 00am to 5 00pm PST World Wide Web http support dlink com E mail support dlink com Canada Telephone 800 361 5265 Monday through Friday 7 30am to 9 00pm EST World Wide Web http support dlink ca E mail support dlink ca Version 1 0 Revised 12 15 2005 6DWS1008ML01G 2005 D...

Reviews: