DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
161
After clicking the
Edit
button, the following page will appear.
Figure 8-9 ACL Access List (Edit) Window
After clicking the
Edit
button, the fields that can be configured are described below:
Parameter
Description
Start Sequence No.
Enter the start sequence number here.
Step
Enter the sequence number step here. The step range is from 1 to 32. This
specifies the number that the sequence numbers step. The default value is 10.
For example, if the increment (step) value is 5 and the beginning sequence
number is 20, the subsequent sequence numbers are 25, 30, 35, 40, and so on.
Counter State
Select to enable or disable the counter state option here.
Remark
Enter an optional remark that will be associated with this ACL here.
Click the
Apply
button to accept the changes made.
After clicking the
Add ACL
button, the following page will appear.
Figure 8-10 ACL Access List (Add ACL) Window
After clicking the
Add ACL
button, the fields that can be configured are described below:
Parameter
Description
ACL Type
Select the ACL type that will be created here. Options to choose from are
Standard IP ACL
,
Extended IP ACL
,
Standard IPv6 ACL
,
Extended IPv6 ACL
,
and
Extended MAC ACL
.
ID
Enter the ID for the ACL here.
•
For a
Standard IP ACL
, the range from 1 to 1999.
•
For an
Extended IP ACL
, the range from 2000 to 3999.