DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
154
IPv4
After clicking the
IPv4
radio button and the
Next
button, the following window will appear.
Figure 8-5 ACL Configuration Wizard (Create, Packet Type, IPv4) Window
The fields that can be configured are described below:
Parameter
Description
Sequence No.
Enter the ACL rule number here. This value must be between 1 and 65535. Select
Auto Assign
to automatically generate an ACL rule number for this entry.
Protocol Type
Select the protocol type option here. Options to choose from are
TCP
,
UDP
,
ICMP
,
EIGRP
(88),
ESP
(50),
GRE
(47),
IGMP
(2),
OSPF
(89),
PIM
(103),
VRRP
(112),
IP-in-IP
(94),
PCP
(108),
Protocol ID
, and
None
.
•
Value
- The protocol ID can also manually be entered here. The range is
from 0 to 255.
•
Fragments
- Select this option to include packet fragment filtering.
The fields that can be configured in
Assign rule criteria
are described below:
Parameter
Description
Source
Select and enter the source information here. Options to choose from are
Any
,
Host
, and
IP
.
•
When the
Any
option is selected, any source traffic will be evaluated
according to the conditions of this rule.
•
When the
Host
option is selected, enter the source host IP address here.