3
It is possible to run this unit in either MANUAL MODE or AUTO MODE. By pressing the
AUTO/MANUAL button is possible to switch between modes. The screen will look like the illustration
below when switching to AUTO MODE.
In AUTO MODE, the fixation unit will automatically turn on the fume buster and raise the up/down
roller once the HEATER 1 SV reaches the temperature value in HEATER 1 PV.
Then, the fixation unit will automatically turn off the fume buster, the heater and lower the up/down
roller after X seconds since the moment the carriage have reached the home position (home sensor).
The “X seconds” or timers can be regulated in the LCD panel (“HEATER 1 OFF”, “SUCTION OFF”
and “ROLLER DOWN”)