Version 1.0

Yellow/green

Earth(Ground)

Operation

The  LEDE 100B can operate in three different modes� In each mode you can run the fixture as a stand 
alone fixture or in a master/slave confiugration� This next section will detail the dif-ferences in the 
operating modes�

Addressing

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture
responds to the correct control signals� This digital starting address is the channel number from which 
the fixture starts to listen to the digital control information sent out from the DMX controller� The 
allocation of this starting address is achieved by setting the correct number on the display located on 
the base of the device�

You can set the same starting address for all fixtures or a group of fixtures, or make different address 
for
each fixture individually�

If you set the same address, all the units will start to listen to the same control signal from the same 
channel number� In other words, changing the settings of one channel will affect all the fixtures 
simultaneously�

If you set a different address, each unit will start to listen to the channel number you have set, based on 
the quantity of control channels of the unit� That means changing the settings of one channel will affect 
only the selected fixture�

In the case of the  LEDE 100B, which is 16 channels fixture� If you set, for example, the address in the 
16 channel mode to channel 17, the device will use the channel 17 to 32 for control�

Universal DMX Control

This function allows you to use a universal DMX-512 controller to control the chases and patterns, 
dimmer and strobe� A DMX controller allows you to create unique programs tailored to your individual 
needs�

Auto run mode

In this mode, you can run internal program without a controller�
1�  Press the MENU button until “

MODE

” is displayed, and press ENTER�

2�  Press the UP or DOWN button so that “

Auto run

” is displayed�

3�  The unit will now run auto mode without a DMX controller�

Sound Mode

This mode allows either single unit or several units linked together, to run to the beat of the music�
1�  Press the MENU button until “

MODE

” is displayed, and press ENTER�

2�  Press the UP or DOWN button so that “

Sound ctrl

” is displayed� 

3�  The unit will now run to the beat of the music�

Master-Slave Operation

This function will allow you to link up to 16 units together and operate without a controller� In a Master-
Slave set up one unit will act as the controlling unit and the others will react to the controlling units 
programs� Any unit can act as a Master or as a Slave�
1�  Using approved DMX data cables, daisy chain your units together via the XLR connector on the rear 

Summary of Contents for LEDE 100B

Page 1: ...USER MANUAL LEDE 100B 100 watts Compact LED Beam Moving Head...

Page 2: ...4 Mounting the fixture on a truss 4 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Operation 6 Addressing 6 Universal DMX Control 6 Auto run mode 6 Sound Mode 6 Master...

Page 3: ...n period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructi...

Page 4: ...d it on a surface or leave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely an...

Page 5: ...xt fixture Always connect one output with the input of the next fixture until all fixtures are connected DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long...

Page 6: ...ans changing the settings of one channel will affect only the selected fixture In the case of the LEDE 100B which is 16 channels fixture If you set for example the address in the 16 channel mode to ch...

Page 7: ...ed DISP Screen saver Off Display shut off time always on Mod 1 Display blackout Mod 2 Show DMX address and control mode Mod 3 Show brand icons Screen Rot Auto Screen reverse Reverse Forward DMX Indica...

Page 8: ...strobe slow fast 192 255 Random strobe slow fast CH7 Dimmer 000 255 0 100 dimmer CH8 Color wheel 000 005 Open hole Color 006 011 Color 1 012 017 Color 2 018 023 Color 3 024 028 Color 4 029 034 Color...

Page 9: ...0 255 Focus CH16 Reset 000 127 No function 128 255 Reset in 3sec Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out p...

Page 10: ...ame size and rating only 3 Reinstall the fuseholder cap before reapplying power Troubleshooting Listed below are a few common problems that you may encounter with solutions The fixture does not work n...

Page 11: ...Electronic variable strobe Static gobo 13 gobos open Rotating gobo 7 gobos open Gobo shake function Prism 16 facet circular prism Frost Control protocols DMX Sound Master Slave Auto Run Control channe...